Refrigeration Cycles And Systems - 1


10 Questions MCQ Test Topicwise Question Bank for GATE Mechanical Engineering | Refrigeration Cycles And Systems - 1


Description
This mock test of Refrigeration Cycles And Systems - 1 for Mechanical Engineering helps you for every Mechanical Engineering entrance exam. This contains 10 Multiple Choice Questions for Mechanical Engineering Refrigeration Cycles And Systems - 1 (mcq) to study with solutions a complete question bank. The solved questions answers in this Refrigeration Cycles And Systems - 1 quiz give you a good mix of easy questions and tough questions. Mechanical Engineering students definitely take this Refrigeration Cycles And Systems - 1 exercise for a better result in the exam. You can find other Refrigeration Cycles And Systems - 1 extra questions, long questions & short questions for Mechanical Engineering on EduRev as well by searching above.
QUESTION: 1

Air refrigeration cycle is generally employed in

Solution:
QUESTION: 2

Which is usually the costliest item in a refrigeration system?

Solution:
QUESTION: 3

In a vapour compression refrigeration system, a throttle valve is used in place of expander because

Solution:

There are practical difficulties in smoothly expanding a liquid of a highly wet vapour in an expander. As vg → vf, the positive work of isentropic expansion is seldom large enough to justify the cost of an expander. The the rmodynamic and friction losses of an expander if employed, may even exceed the gain in work. Accordingly, the isentropic expansion process may be replaced by the use of an expansion device such as a throttle valve or a capillary tube.

QUESTION: 4

The bank of tubes at the back of a domestic refrigerator of vapour compression type are

Solution:

These tubes are air-cooled condenser which are used only in small capacity machines, such as refrigerators and small water coolers which use vertical wire and tube or plate and tube construction with natural circulation, and window type and packaged air conditioners which have tubes with 5-7 fins per cm and use forced circulation of air.

QUESTION: 5

For small installations of refrigeration systems (up to 35 kW), which type of condenser is used?

Solution:

Air-cooled condensers used only in small capacity machines. Air cooled condensers are seldom made in sizes over 5 TR because of high head pressure, excessive power consumption and objectionable fan noise. In air-cooled condensers, heat is removed by air using either natural or forced circulation.

QUESTION: 6

The pressure in a capillary tube decreases due to which of the following:

1. frictional resistance offered by the tube wall
2. acceleration of refrigerant in the tube
3. heat transfer from the tube
4. decrease in potential energy

Q. Which of the above statements are correct?

Solution:
QUESTION: 7

An ideal vapour compression refrigerator operates between a condenser pressure P1 and an evaporator pressure P2. Which of the following changes would increase its COP?

Solution:

COP decreases both with decreasing evaporator and increasing condenser pressures. The COP increases by installing a subcooler between the condenser and the expansion valve. The subcooling reduces flashing of the liquid during expansion and increases refrigerating effect.

QUESTION: 8

Which of the following parameters is made as basis of comparing different type of air- refrigeration systems?

Solution:

DART (Dry air rated temperature): It is the temperature of the discharge air from the expander if there is no condensed moisture present and is calculated by specific procedure. The refrigerating capacity of the air cycle unit in kW has no particular relevance. The refrigerating capacity is usually expressed in terms of the mass flow rate of air at DART. In a modern jet aircraft, typical values are 1.8 kg/s of air at 10°C DART just after take-off, and 1.4 kg/s of air at 12.8°C when the aircraft is cruising.

QUESTION: 9

The following figure compares different aircraft refrigeration systems. Match List-I with List-ll pertaining to comparison of DART vs. Mach number variation


Solution:
QUESTION: 10

Lowest COP is of vapour

Solution: