A 3-phase synchronous motor of 10 KW at 1.3 kV has a synchronous reactance of 10 Ω/phase. The efficiency of the machine is 75%. Find input power for the motor.
A synchronous motor with negligible armature resistance runs at a load angle of 20° at the rated frequency. If supply frequency is increased by 10%, keeping the other parameters constant, the new load angle will be
1 Crore+ students have signed up on EduRev. Have you? Download the App |
The per phase circuit equivalent of a synchronous generator feeding a synchronous motor through a transmission line is shown in fig. Each machine is rated 10 kVA, 400V, 50 Hz. The motor is driving a load of 8 kW. The field current of the two machine are so adjusted that the motor terminal voltage is 400V and its pf is 0.8 leading. Find the minimum value of Em (in P.U) for the machine to remain in synchronism.
The rotor of a 50 Hz, 4 poles, 3ϕ synchronous motor is directly coupled to the rotor of a 50 Hz, 6 poles induction motor. If the stators of both machines are given balanced 3ϕ, 50 Hz supplies of rated voltage values. The possible induced frequencies in the rotor of induction motor are-
A cylindrical rotor synchronous motor is used to improve the power factor of a load 5 MW at a power factor of 0.6 lag. The motor is required to meet an additional demand of 0.2 MW and raise the overall power factor to 0.8 (lag). If the efficiency of the motor is 75%. The power factor of the motor is – (up to two decimal places)
A 60 MVA, 11 kV, 50 Hz, Y connected, 3 phase salient pole synchronous motor has direct axis synchronous reactance Xd = 1.8 Ω and quadrature axis synchronous reactance Xq = 1.2 Ω. If the armature resistance is negligible and full load power factor is 0.8 log. The power angle is-
A 3-phase synchronous motor of 10 KW at 1.3 kV has synchronous reactance of 10 Ω/phase. The efficiency of the machine is 75%. The induced emf (per phase) corresponding to minimum current for full load condition is ____ (in V). Neglect armature resistance.
A 400 V, 3ϕ delta connected synchronous motor runs at rated voltage and with an excitation emf of 500 V. Its winding and iron losses are 1800 W and synchronous impedance per phase is (0.7 + 3j) Ω. Calculate the shaft power output in kW
The maximum power delivered by 1500 kW, three phase star connected 4 kV, 48 pole 50 Hz synchronous motor, with synchronous reactance of 4 Ω per phase and unity power factor is___(in MW)
A 2300 V, 400 h.p, 60 Hz, 8 pole Y connected synchronous motor has a rated power factor of 0.85 leading. At full load, the efficiency 85%. The armature resistance is 0.4, and the synchronous reactance is 4.4 Ω. Find the Ea for this machine when it is operating at full load.