This mock test of Test: Performance Indices for Electrical Engineering (EE) helps you for every Electrical Engineering (EE) entrance exam. This contains 10 Multiple Choice Questions for Electrical Engineering (EE) Test: Performance Indices (mcq) to study with solutions a complete question bank. The solved questions answers in this Test: Performance Indices quiz give you a good mix of easy questions and tough questions. Electrical Engineering (EE) students definitely take this Test: Performance Indices exercise for a better result in the exam. You can find other Test: Performance Indices extra questions, long questions & short questions for Electrical Engineering (EE) on EduRev as well by searching above.
QUESTION: 1

If the performance index of a phase lead compensator is (s+a)/ (s+b) and that of a lag compensator is (s+p)/(s+q), then which one of the following sets of conditions must be satisfied?

Solution:

Answer: d
Explanation: In phase lead compensator, zero is nearer to origin. In phase lag compensator, pole is nearer to origin.

QUESTION: 2

The compensator Gc(s) =5(1+0.3s)/(1+0.1s) would provide a maximum phase shift of: 

Solution:

Answer: c
Explanation: Maximum phase shift sin^(-1)⁡ [(1-α)/(1+α)] and sin^(-1)⁡[1/2] = 30°

QUESTION: 3

The industrial controller having the best steady-state accuracy is:

Solution:

Answer: a
Explanation: The best steady state accuracy is of derivative controller and this is due to the fact that derivative controller is only affected by the steady state response not the transient response.

QUESTION: 4

Assertion (A): An on-off controller gives rise to self-sustained oscillation in output.
Reason (R): Location of a pair of poles on the imaginary axis gives to self-sustained oscillation is output.

Solution:

Answer: a
Explanation: An off-off controller is the initial version of the proportional controller and it gives the self-sustained oscillations and location of poles on the imaginary axis gives the self-sustained oscillations.

QUESTION: 5

Consider the following statement:
A proportional plus derivative controller
1. Has high sensitivity
2. Increases the stability of the system
3. Improves the steady state accuracy

Which of these statements are correct?

Solution:

Answer: b
Explanation: A proportional plus derivative controller has the following features as it adds open loop zero on the negative real axis, peak overshoot decreases, bandwidth increases and rise time decreases.

QUESTION: 6

Which one of the following compensation is required for improving the transient response of the system?

Solution:

Answer: a
Explanation: For increasing or improving the transient response derivative controller is used and which is the phase lead compensation.

QUESTION: 7

Pneumatic controller are :

Solution:

Answer: c
Explanation: Pneumatic controllers are fire and explosion proof operation as they require air and gas fuel for its operation.

QUESTION: 8

Hydraulic controller :

Solution:

Answer: b
Explanation: Hydraulic controller must have no leakage and also it requires high torque and high speed operation due to high density of the controller.

QUESTION: 9

Electronic Controller :

Solution:

Answer: a
Explanation: Flexible in all sense as it does not require heavy components or extra torque or high speed operations.

QUESTION: 10

A plant controlled by a proportional controller. If a time delay element is introduced in the loop its :

Solution:

Answer: c
Explanation: The introduction of a time delay element decreases both the phase and gain margin.