Civil Engineering (CE) Exam  >  Civil Engineering (CE) Tests  >  GATE Civil Engineering (CE) 2025 Mock Test Series  >  Test: Sleepers & Ballast - 1 - Civil Engineering (CE) MCQ

Test: Sleepers & Ballast - 1 - Civil Engineering (CE) MCQ


Test Description

10 Questions MCQ Test GATE Civil Engineering (CE) 2025 Mock Test Series - Test: Sleepers & Ballast - 1

Test: Sleepers & Ballast - 1 for Civil Engineering (CE) 2024 is part of GATE Civil Engineering (CE) 2025 Mock Test Series preparation. The Test: Sleepers & Ballast - 1 questions and answers have been prepared according to the Civil Engineering (CE) exam syllabus.The Test: Sleepers & Ballast - 1 MCQs are made for Civil Engineering (CE) 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Sleepers & Ballast - 1 below.
Solutions of Test: Sleepers & Ballast - 1 questions in English are available as part of our GATE Civil Engineering (CE) 2025 Mock Test Series for Civil Engineering (CE) & Test: Sleepers & Ballast - 1 solutions in Hindi for GATE Civil Engineering (CE) 2025 Mock Test Series course. Download more important topics, notes, lectures and mock test series for Civil Engineering (CE) Exam by signing up for free. Attempt Test: Sleepers & Ballast - 1 | 10 questions in 30 minutes | Mock test for Civil Engineering (CE) preparation | Free important questions MCQ to study GATE Civil Engineering (CE) 2025 Mock Test Series for Civil Engineering (CE) Exam | Download free PDF with solutions
Test: Sleepers & Ballast - 1 - Question 1

For taking the consideration of creep of rails the sleepers that need no anchoring arrangement

Detailed Solution for Test: Sleepers & Ballast - 1 - Question 1

Concrete sleepers are heavy in weight due to their self weight and thus, the need no anchoring.

Test: Sleepers & Ballast - 1 - Question 2

Which of the following incorrectly represents the function of sleepers in the layout of railway tracks?

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Sleepers & Ballast - 1 - Question 3

Metal sleepers are superior to wooden sleepers with respect to

Test: Sleepers & Ballast - 1 - Question 4

The ballast below the sleeper is called

Test: Sleepers & Ballast - 1 - Question 5

Which of the following types of sleepers is preferred on joints?

Test: Sleepers & Ballast - 1 - Question 6

Minimum depth of ballast cushion for a Board Gauge wooden sleeper of size 275 x 25 x 13 cm with 75 cm sleeper spacing is

Detailed Solution for Test: Sleepers & Ballast - 1 - Question 6

Minimum depth of ballast cushion D in terms of sleeper spacing S and width of sleeper W is given by the equation,

Test: Sleepers & Ballast - 1 - Question 7

Sleeper density in India is normally kept as
Where M is the rail length in metres.

Test: Sleepers & Ballast - 1 - Question 8

For a Broad Gauge route with M+7 sleeper density, number of sleepers per rail length is

Detailed Solution for Test: Sleepers & Ballast - 1 - Question 8

Length of one rail in broad gauge is equal to 13 m
Therefore, M+7 means that 13+7=20 sleepers will be used per rail on that route.

Test: Sleepers & Ballast - 1 - Question 9

Standard size of wooden sleeper for Broad gauge track is

Test: Sleepers & Ballast - 1 - Question 10

Composite sleeper index is the index of

31 docs|280 tests
Information about Test: Sleepers & Ballast - 1 Page
In this test you can find the Exam questions for Test: Sleepers & Ballast - 1 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Sleepers & Ballast - 1, EduRev gives you an ample number of Online tests for practice

Top Courses for Civil Engineering (CE)

Download as PDF

Top Courses for Civil Engineering (CE)