Test: Beams & Slabs - 1


Test Description

10 Questions MCQ Test GATE Civil Engineering (CE) 2023 Mock Test Series | Test: Beams & Slabs - 1

Test: Beams & Slabs - 1 for Civil Engineering (CE) 2022 is part of GATE Civil Engineering (CE) 2023 Mock Test Series preparation. The Test: Beams & Slabs - 1 questions and answers have been prepared according to the Civil Engineering (CE) exam syllabus.The Test: Beams & Slabs - 1 MCQs are made for Civil Engineering (CE) 2022 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Beams & Slabs - 1 below.
Solutions of Test: Beams & Slabs - 1 questions in English are available as part of our GATE Civil Engineering (CE) 2023 Mock Test Series for Civil Engineering (CE) & Test: Beams & Slabs - 1 solutions in Hindi for GATE Civil Engineering (CE) 2023 Mock Test Series course. Download more important topics, notes, lectures and mock test series for Civil Engineering (CE) Exam by signing up for free. Attempt Test: Beams & Slabs - 1 | 10 questions in 30 minutes | Mock test for Civil Engineering (CE) preparation | Free important questions MCQ to study GATE Civil Engineering (CE) 2023 Mock Test Series for Civil Engineering (CE) Exam | Download free PDF with solutions
1 Crore+ students have signed up on EduRev. Have you?
Test: Beams & Slabs - 1 - Question 1

A doubly reinforced beam is considered less economical than a singly reinforced beam because

Detailed Solution for Test: Beams & Slabs - 1 - Question 1

Since the maximum compressive stress is not reached in doubly reinforced beam compressive steel. This is because the we need to find the compressive stress depending on the strain in beam and thus, the stress obtained for all the practical case is less than fy.

Test: Beams & Slabs - 1 - Question 2

The maximum percentage of moment redistribution allowed in RCC beams is

Detailed Solution for Test: Beams & Slabs - 1 - Question 2

As per clause 37.1.1 of IS: 456-2000 the ultimate moment of resistance at any section should not be less than 70% of the factored moment at that section as obtained from the elastic moment envelope (considering all loading combinations).

Test: Beams & Slabs - 1 - Question 3

Partial safety factor for concrete and steel are 1.5 and 1.15 respectively, because

Detailed Solution for Test: Beams & Slabs - 1 - Question 3

Steel Is produced in factory in which controlled environment is possible. However, concrete is produced at site itself leading to more chances of carelessness. Thus, higher factor of safety for concrete in comparison to steel.

Test: Beams & Slabs - 1 - Question 4

In the design of two-way slab restrained at all edges, torsional reinforcement required is

Test: Beams & Slabs - 1 - Question 5

A reinforced concrete slab is 75 mm thick. The maximum size of reinforcement bar that can be  used is of

Detailed Solution for Test: Beams & Slabs - 1 - Question 5

The diameter of the bars shall not exceed one eight of the total thickness of the slab. 

∴  Maximum size = 75/8= 9.375 mm
So the diameter will be 8 mm.

Test: Beams & Slabs - 1 - Question 6

In the limit state method, balanced design of a reinforced concrete beam gives

Detailed Solution for Test: Beams & Slabs - 1 - Question 6

Balanced Design means both concrete and steel will fail at the same time. Thus, it gives optimum smallest concrete section for a given reinforcement and maximum reinforcement for a given concrete section. 

Test: Beams & Slabs - 1 - Question 7

In case of simply supported beam , the clear distance between lateral restraints shall not exceed

Detailed Solution for Test: Beams & Slabs - 1 - Question 7

As per IS 456:2000 for lateral stability, the clear span of
Simply supported beam should be less than 60b or 250(b2)/d 
Cantilever Beam should be less than 25b or 100(b2)/d

Test: Beams & Slabs - 1 - Question 8

When shear reinforcement is not provided in flat slab, the calculated shear stress at the critical section shall not exceed Ks ζc, where Ks is 

Where βc is ratio of short side to long side of column capital.

Detailed Solution for Test: Beams & Slabs - 1 - Question 8

Test: Beams & Slabs - 1 - Question 9

In case of 2-way slab, the limiting deflection of the slab is

Detailed Solution for Test: Beams & Slabs - 1 - Question 9

The strip of a two way slab may be checked against shorter span to effective depth ratios.

Test: Beams & Slabs - 1 - Question 10

The main reinforcement of a RC slab consists of 10 mm bars at 10 cm spacing. If it is desired to replace 10 mm bars by 12 mm bars, then the spacing of 12 mm bars should be

Detailed Solution for Test: Beams & Slabs - 1 - Question 10

The horizontal distance between parallel main reinforcement bars shall not be more than three times the effective depth of solid slab or 300 mm whichever is smaller. The total reinforcement in the slab should remain same. By replacing 10 mm bars by 12 mm bars, the spacing will increase as

Use Code STAYHOME200 and get INR 200 additional OFF
Use Coupon Code
Information about Test: Beams & Slabs - 1 Page
In this test you can find the Exam questions for Test: Beams & Slabs - 1 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Beams & Slabs - 1, EduRev gives you an ample number of Online tests for practice