Test: Evaporators for Mechanical Engineering 2024 is part of Heat Transfer preparation. The Test: Evaporators questions and answers have been prepared according to the Mechanical Engineering exam syllabus.The Test: Evaporators MCQs are made for Mechanical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Evaporators below.
Solutions of Test: Evaporators questions in English are available as part of our Heat Transfer for Mechanical Engineering & Test: Evaporators solutions in Hindi for Heat Transfer course. Download more important topics, notes, lectures and mock test series for Mechanical Engineering Exam by signing up for free. Attempt Test: Evaporators | 10 questions in 20 minutes | Mock test for Mechanical Engineering preparation | Free important questions MCQ to study Heat Transfer for Mechanical Engineering Exam | Download free PDF with solutions
Test: Evaporators - Question 1

What is the purpose of chemical spraying on finned evaporators?

Detailed Solution for Test: Evaporators - Question 1

Finned evaporator:

  • The finned evaporators consist of bare tubes or coils over which the total plates or fins are fastened.
  • The metal fins are constructed of thin sheets of metal having good thermal conductivity.
  • Since the fins greatly increase the contact surfaces for heat transfer, therefore the finned evaporators are also called extended surface evaporators.
  • The finned evaporators are primarily designed for air conditioning applications where the refrigerator temperature is above 0°C.
  • Because of the rapid heat transfer of the finned evaporator, it will defrost itself on the off cycle when the temperature of the coil is near 0°C.
  • Moisture in the air causes rusty formation on the Aluminium fins and it can be cleared by spraying rust-removing chemicals when the unit is under service.

Test: Evaporators - Question 2

If the amount of water vapour in the air is high, then the rate of evaporation is ______.

Detailed Solution for Test: Evaporators - Question 2

The correct answer is Will decrease.

  • If the humidity in the atmosphere is high, the rate of evaporation is low because the air is filled with water vapor and is not able to take up more humidity. Thus, the evaporation process slows down.
1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Evaporators - Question 3

Dry evaporator is one in which?

Detailed Solution for Test: Evaporators - Question 3

In the dry evaporator, the liquid refrigerant is generally fed by an expansion valve. The valve controls the rate of flow of refrigerant in such a way that all the liquid is vaporised, and the vapour is also superheated by the time it reaches the evaporator exit.

Test: Evaporators - Question 4

What is the state of the refrigerant when it enters into the evaporator?

Detailed Solution for Test: Evaporators - Question 4

The refrigerant at the entry to the evaporator is low pressure and low temperature liquid. The pressure is reduced in the capillary tube thus also decreasing the temperature. This low pressure, low temperature liquid is converted to low pressure vapours after absorbing heat from the evaporator.

Test: Evaporators - Question 5

Frost is formed on cooling coils due to ______

Detailed Solution for Test: Evaporators - Question 5

The moisture present in the evaporator section of refrigerator is cooled and converted to the frost. This ice formed affects the heat transfer rate in the evaporator and increase the electricity consumption.

Test: Evaporators - Question 6

Which is simplest type of evaporator.

Detailed Solution for Test: Evaporators - Question 6

Types of Evaporator:

  • Bare tube Evaporator: These are constructed of either steel pipe or copper tubing. These are the simplest type of evaporators. Steel pipe is used for large evaporators and the copper tube is used for smaller evaporators. Common shapes are zig-zag flat or spiral. These are used where the temperature is maintained below 0°C.
  • Plate Surface Evaporator: These are made up of two flat sheets of metal so embossed and welded together to provide a path for refrigerant flow between two sheets. It is usually cleaned and defrosted manually. It is used in domestic refrigerators.
  • Finned Tube Evaporators: Finned coil is bare tube coil upon which metal plates or fins are installed. The use of fins increases the overall surface area of the evaporator.
Test: Evaporators - Question 7

The refrigerator’s evaporator can also be termed as

Detailed Solution for Test: Evaporators - Question 7

Evaporator is the heat absorbing part of the refrigeration system. This is also called cooling coil, freezer or chiller. These names are according to their function in the system. In the domestic refrigerator it is termed as freezer.

Test: Evaporators - Question 8

In the evaporator of refrigerator system, the refrigerant changes from ______

Detailed Solution for Test: Evaporators - Question 8

Refrigeration is a process of heat removal from a substance or from a space resulting in lower temperature below that of the surroundings. Major parts of the conventional refrigeration system are as followed.

Evaporator: It is the part where cooling takes place. The heat is absorbed in the evaporator. The liquid refrigerant is converted into vapour refrigerant in the evaporator.

Condenser: The function of the condenser is to remove the heat carried by the refrigerant and reduce its temperature at constant pressure.

Receiver: It is the reservoir for excess liquid refrigerant not being in the system.

Test: Evaporators - Question 9

A suction line liquid line heat exchanger cause

Detailed Solution for Test: Evaporators - Question 9

A liquid line and suction line heat exchanger are used to transfer heat between liquid refrigerant leaving the condenser on the high-pressure side of the system and refrigerant vapour leaving the evaporator on the low-pressure side of the system.

This heat transfer causes following effects

  • To raise the vapour temperature (Superheating) to prevent frosting or condensation on the suction line
  • To evaporate any remaining liquid in the vapour stream to prevent possible compressor damage
  • To sub-cool the liquid to prevent flash gas in the liquid line
  • To increase the system refrigerating capacity

Test: Evaporators - Question 10

Plate type evaporators are employed in

Detailed Solution for Test: Evaporators - Question 10

Types of Evaporator:

  • Bare tube Evaporator: These are constructed of either steel pipe or copper tubing. These are simplest type of evaporators. Steel pipe is used for large evaporators and copper tube is used for smaller evaporators. Common shapes are zig-zag flat or spiral. These are used where temperature is maintained below 0°C.
  • Plate Surface Evaporator: These are made up of two flat sheets of metal so embossed and welded together as to provide a path for refrigerant flow between two sheets. It is usually cleaned and defrosted manually. It is used in domestic refrigerators.
  • Finned Tube Evaporators: Finned coil are bare tube coil upon which metal plates or fins are installed. The use of fins increases the overall surface area of evaporator.