Lecture 18 - Bode Plot - Electrical Engineering (EE) PDF Download

Lecture 18 - Bode Plot, Control Systems

 

1 Bode Plot

Bode plot is the graphical tool for drawing the frequency response of a system.
It is represented by two separate plots, one is the magnitude vs frequency and the other one is phase vs frequency.The magnitude is expressed in dB and the frequency is generally plotted in log scale.

One of the advantages of the Bode plot in s-domain is that the magnitude curve can be approximated by straight lines which allows the sketching of the magnitude plot without exact computation.

This feature is lost when we plot Bode diagram in z-domain . To incorporate this feature we use bi-linear transformation to transform unit circle of the z-plane into the imaginary axis of another complex plane, w plane, where

Lecture 18 - Bode Plot - Electrical Engineering (EE)

From the power series expansion

Lecture 18 - Bode Plot - Electrical Engineering (EE)

For frequency domain analysis the above bi-linear transformation may be used to convert GH (z) to GH (w) and then construct the Bode plot.

Example 1: Let us consider a digital control system for which the loop transfer function is given by

Lecture 18 - Bode Plot - Electrical Engineering (EE)

where sampling time T = 0.1 sec. Putting z =Lecture 18 - Bode Plot - Electrical Engineering (EE) we get the transfer function in w plane as

Lecture 18 - Bode Plot - Electrical Engineering (EE)

where ωw is the frequency in w plane. Corner frequencies are 1/1.0026 = 0.997 rad/sec and 1/0.05 = 20 rad/sec.

The straight line asymptotes of the Bode plot can be drawn using the following.

  • Up to ωw = 0.997 rad/sec, the magnitude plot is a straight line with slope −20 dB/decade. At ωw = 0.01 rad/sec, the magnitude is 20 log10(10.02)−20 log10(0.01) = 60 dB.
  • From ωw = 0.997 rad/sec to ωw = 20 rad/sec, the magnitude plot is a straight line with slope −20 − 20 = −40 dB/decade.
  • Since both of the zeros will contribute same to the magnitude plot, after ωw = 20 rad/sec, the slope of the straight line will be −40 + 20 + 20 = 0dB/decade.

The asymptotic magnitude plot is shown in Figure 1.

One should remember that the actual plot will be slightly different from the asymptotic plot.

In the actual plot, errors due to straight line assumptions is compensated.

Phase plot is drawn by varying the frequency from 0.01 to 100 rad/sec at regular intervals. The phase angle contributed by one zero will be canceled by the other. Thus the phase will vary from −90o(270o) to −180o(180o).

Figure 2 shows the actual magnitude and phase plot as drawn in MATLAB.

Lecture 18 - Bode Plot - Electrical Engineering (EE)

Bode Diagram

Lecture 18 - Bode Plot - Electrical Engineering (EE)

Figure 2: Bode magnitude and phase plot for Example 1


1.1 Gain margin and Phase margin 

Gain margin and phase margins are the measures of relative stability of a system.

Similar to continuous time case, we have to first define phase and gain cross over frequencies before defining gain margin and phase margin.

Gain margin is the safety factor by which the open loop gain of a system can be increased before the system becomes unstable. It is measured as

Lecture 18 - Bode Plot - Electrical Engineering (EE)

where ωp is the phase crossover frequency which is defined as the frequency where the phase of the loop transfer function GH (eiωT ) is 180o .

Similarly Phase margin (PM) is defined as

P M = 180+ GH (eiωg T )

where ωg is the gain crossover frequency which is defined as the frequency where the loop gain magnitude of the system becomes one.

 

1.2 Compensator design using Bode plot 

A compensator or controller is added to a system to improve its steady state as well as dynamic responses.
Nyquist plot is difficult to modify after introducing controller.
Instead Bode plot is used since two important design criteria, phase margin and gain crossover frequency are visible from the Bode plot along with gain margin.
 

Points to remember

  •  Low frequency asymptote of the magnitude curve is indicative of one of the error constants Kp, Kv , Ka depending on the system types.
  • Specifications on the transient response can be translated into phase margin (PM), gain margin (GM), gain crossover frequency, bandwidth etc.
  • Design using bode plot is simple and straight forward.
  • Reconstruction of Bode plot is not a difficult task.

 

1.3 Phase lead, Phase lag and Lag-lead compensators 

Phase lead, phase lag and lag-lead compensators are widely used in frequency domain design.

Before going into the details of the design procedure, we must remember the following.

  • Phase lead compensation is used to improve stability margins. It increases system bandwidth thus improving the spread of the response.
  • Phase lag compensation reduces the system gain at high frequencies with out reducing low frequency gain. Thus the total gain/low frequency gain can be increased which in turn will improve the steady state accuracy. High frequency noise can also be attenuated. But stability margin and bandwidth reduce.
  • Using a lag lead compensator, where a lag compensator is cascaded with a lead compensator, both steady state and transient responses can be improved.

Bi-linear transformation transfers the loop transfer function in z -plane to w-plane.

Since qualitatively w-plane is similar to s-plane, design technique used in s-plane can be employed to design a controller in w-plane.

Once the design is done in w-plane, controller in z-plane can be determined by using the inverse transformation from w-plane to z -plane.

In the next two lectures we will discuss compensator design in s-plane and solve examples to design digital controllers using the same concept. 

The document Lecture 18 - Bode Plot - Electrical Engineering (EE) is a part of Electrical Engineering (EE) category.
All you need of Electrical Engineering (EE) at this link: Electrical Engineering (EE)

Top Courses for Electrical Engineering (EE)

FAQs on Lecture 18 - Bode Plot - Electrical Engineering (EE)

1. What is a Bode plot?
Ans. A Bode plot is a graphical representation of the frequency response of a system. It shows the magnitude and phase response of the system as a function of frequency.
2. How is a Bode plot useful in control systems?
Ans. A Bode plot helps in analyzing the stability and performance of a control system. It provides insights into the gain and phase margins, which indicate the system's stability. It also helps in understanding the frequency response characteristics, such as bandwidth and resonant frequencies.
3. How do you interpret the magnitude plot in a Bode plot?
Ans. The magnitude plot in a Bode plot represents the gain of the system at different frequencies. It is usually expressed in decibels (dB). The plot shows how the system amplifies or attenuates the input signal at different frequencies. The magnitude plot can be used to determine the resonant frequency, bandwidth, and overall gain characteristics of the system.
4. What does the phase plot in a Bode plot indicate?
Ans. The phase plot in a Bode plot represents the phase shift between the input and output signals of the system at different frequencies. It is usually measured in degrees. The phase plot helps in understanding the time delay and phase lag introduced by the system. It is crucial for analyzing the stability and transient response of the control system.
5. How can Bode plots be used in designing control systems?
Ans. Bode plots can be used in designing control systems by providing valuable insights into the system's frequency response characteristics. The gain and phase margins obtained from the Bode plot can guide the selection of controller parameters to ensure stability. The Bode plot also helps in determining the bandwidth requirements and adjusting the system's dynamics for desired performance specifications.
Download as PDF
Explore Courses for Electrical Engineering (EE) exam

Top Courses for Electrical Engineering (EE)

Signup for Free!
Signup to see your scores go up within 7 days! Learn & Practice with 1000+ FREE Notes, Videos & Tests.
10M+ students study on EduRev
Related Searches

shortcuts and tricks

,

Semester Notes

,

Objective type Questions

,

Summary

,

Lecture 18 - Bode Plot - Electrical Engineering (EE)

,

Viva Questions

,

Important questions

,

Extra Questions

,

pdf

,

Previous Year Questions with Solutions

,

practice quizzes

,

Free

,

past year papers

,

video lectures

,

Lecture 18 - Bode Plot - Electrical Engineering (EE)

,

mock tests for examination

,

Sample Paper

,

study material

,

MCQs

,

ppt

,

Lecture 18 - Bode Plot - Electrical Engineering (EE)

,

Exam

;