Past Year Questions: Psychrometric Process Notes | EduRev

Thermodynamics

Mechanical Engineering : Past Year Questions: Psychrometric Process Notes | EduRev

The document Past Year Questions: Psychrometric Process Notes | EduRev is a part of the Mechanical Engineering Course Thermodynamics.
All you need of Mechanical Engineering at this link: Mechanical Engineering

Question 1:Wet bulb depression, under saturated ambient air conditions:

Question 2:During the Chemical dehumidification process of air

Question 3:Water at 42°C is sprayed into a stream of air at atmospheric pressure, dry bulb temperature of 40ºC and a wet bulb temperature of 20°C. The air leaving the spray humidifier is not saturated. Which of the following statements is true?

Question 4:Various psychrometric processes are shown in the figure below.
Process in Figure
P. 0-1
Q. 0-2
R. 0-3
S. 0-4
T. 0-5

Name of the process
(i) Chemical dehumidification
(ii) Sensible heating
(iii) Cooling and dehumidification
(iv) Humidification with steam injection
(v) Humidification with water injection

Past Year Questions: Psychrometric Process Notes | EduRev
The matching pair are

Question 5:Dew point temperature is the temperature at which condensation begins when the air is cooled at constant

Question 6:The statements concern psychrometric chart.
1. Constant relative humidity lines are uphill straight lines to the right.
2. Constant wet bulb temperature lines are downhill straight lines to the right.
3. Constant specific volume lines are downhill straight lines to the right.
4. Constant enthalpy lines are coincident with constant wet bulb temperature lines.
Which of the statements are correct?

Question 7:Atmospheric air at a flow rate of 3 kg/s (on dry basis) enters a cooling and dehumidifying coil with an enthalpy of 85 kJ/kg of dry air and a humidity ratio of 19 grams/kg of dry air. The air leaves the coil with an enthalpy of 43 kJ/kg of dry air and a humidity ratio of 8 grams/kg of dry air. If the condensate water leaves the coil with an enthalpy of 67 kJ/kg, the required cooling capacity of the coil in kW is

Question 8:Air (at atmospheric pressure) at a dry bulb temperature of 40°C and wet bulb temperature of 20°C is humidified in an air washer operating with continuous water recirculation. The wet bulb depression, the difference between the dry and wet bulb temperatures) at the exit is 25% of that at the inlet. The dry bulb temperature at the exit of the air washer is closest to

Question 9:Moist air at 35°C and 100% relative humidity is entering a psychrometric device and leaving at 25°C and 100% relative humidity. The name of the device is

Question 10:If a mass of moist air contained in a closed metallic vessel is heated, then its


Offer running on EduRev: Apply code STAYHOME200 to get INR 200 off on our premium plan EduRev Infinity!

Related Searches

Objective type Questions

,

Free

,

Previous Year Questions with Solutions

,

past year papers

,

MCQs

,

study material

,

Past Year Questions: Psychrometric Process Notes | EduRev

,

Summary

,

Important questions

,

pdf

,

practice quizzes

,

shortcuts and tricks

,

Exam

,

Semester Notes

,

Viva Questions

,

Sample Paper

,

video lectures

,

mock tests for examination

,

ppt

,

Past Year Questions: Psychrometric Process Notes | EduRev

,

Extra Questions

,

Past Year Questions: Psychrometric Process Notes | EduRev

;