Electrical Engineering (EE) Exam  >  Electrical Engineering (EE) Tests  >  Test: Utilization of Electrical Energy- 1 - Electrical Engineering (EE) MCQ

Test: Utilization of Electrical Energy- 1 - Electrical Engineering (EE) MCQ


Test Description

20 Questions MCQ Test - Test: Utilization of Electrical Energy- 1

Test: Utilization of Electrical Energy- 1 for Electrical Engineering (EE) 2024 is part of Electrical Engineering (EE) preparation. The Test: Utilization of Electrical Energy- 1 questions and answers have been prepared according to the Electrical Engineering (EE) exam syllabus.The Test: Utilization of Electrical Energy- 1 MCQs are made for Electrical Engineering (EE) 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Utilization of Electrical Energy- 1 below.
Solutions of Test: Utilization of Electrical Energy- 1 questions in English are available as part of our course for Electrical Engineering (EE) & Test: Utilization of Electrical Energy- 1 solutions in Hindi for Electrical Engineering (EE) course. Download more important topics, notes, lectures and mock test series for Electrical Engineering (EE) Exam by signing up for free. Attempt Test: Utilization of Electrical Energy- 1 | 20 questions in 12 minutes | Mock test for Electrical Engineering (EE) preparation | Free important questions MCQ to study for Electrical Engineering (EE) Exam | Download free PDF with solutions
Test: Utilization of Electrical Energy- 1 - Question 1

Which of the followings falls under the category of the plastic or non-fusion welding?

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 1

Plastic or Non fusion welding: In this welding, the pieces of metal to be joined are heated to a plastic state and then forced together by external pressure. This procedure is used in forge welding, resistance welding, thermit welding and gas welding.

Fusion or Non pressure welding: In the fusion welding, the material at the joint is heated to a molten state and allowed to solidify. This includes gas welding, arc welding etc.

Cold welding: In this welding, the joints are produced without the application of heat but by applying pressure which results in inter-surface molecular fusion of the parts to be joined. This process is mainly used for welding nonferrous sheet metal.

Test: Utilization of Electrical Energy- 1 - Question 2

The proper selection of welding depends upon, in addition to cost involved:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 2

The selection of proper welding depend on the following factors

1. The type of metal to be joined

2. The techniques of welding adopted

3. The cost of equipment used

4. The nature of products to be fabricated

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Utilization of Electrical Energy- 1 - Question 3

In the upset butt welding:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 3

In upset butt welding, the two metal parts to be welded are joined end to end and are connected across the secondary of a welding transformer

Due to the contact resistance of the metals to be welded, heating effect is generated in this welding.

The voltage required is 2-8 V and the current required ranges from 50 A to several hundred amperes depending upon material and the area to be welded at a time

Test: Utilization of Electrical Energy- 1 - Question 4

The electric arc has:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 4

Electric arc welding is the process of joining two metallic pieces. In this, melting of metal is obtained due to the heat developed by an arc struck between an electrode and the metal to be welded or between the two electrodes

When the supply is given across the conductors separated by some distance apart, the air gap present between the two conductors gets ionized. As the arc welding in progress, the ionization of the arc path and its surrounding area increases

The increase in ionization decreases the resistance of the path. Thus, current increases with the decrease in voltage of arc. It indicates that, arc has negative resistance characteristics

Test: Utilization of Electrical Energy- 1 - Question 5

A rectifier used for welding has voltage current characteristic as:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 5

Drooping V-I characteristic is used on constant current type welding machine. When arc is struck in arc welding machine electoral is essentially in short circuit which would immediately require a sudden of current otherwise machine is designed to Prevent this. A constant current machine is designed to minimized these sudden surges.

Test: Utilization of Electrical Energy- 1 - Question 6

Which of the following filament material has the lowest melting point?

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 6

Test: Utilization of Electrical Energy- 1 - Question 7

In electric discharge lamps, for stabilization of arc:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 7

In electric discharge lamps, a choke is connected in series with the supply to limit the starting current and to stabilize the arc.

Test: Utilization of Electrical Energy- 1 - Question 8

When a sodium vapor lamp is switched on, initially the color is:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 8

Initially the sodium is in the form of a sloid, deposited on the walls of inner tube. When sufficient voltage is impressed across the electrodes, the discharge starts in the inert gas (neon). It operates as a low pressure neon lamp with pink colour

Test: Utilization of Electrical Energy- 1 - Question 9

The type of drive used for a paper mill requiring a constant speed operation and the flexibility of control is:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 9

Group drives: Electric drive that is used to drive two or more than two machines from line shaft through belts and pulleys is known as group drive

Individual drive: A single electric motor is used to drive one individual machine.

Multi-motor drive: Several separate motors are provided for operating different parts of the single machine

For a paper mill requiring a constant speed operation and the flexibility of control we can use Individual or multi-motor drive

Test: Utilization of Electrical Energy- 1 - Question 10

The least significant electrical characteristic in the selection of the electric motor for a flour mill is:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 10

In the selection of the electric motor for a flour mill, starting torque and running torque both are important. Braking is least significant electrical characteristic for this purpose

Test: Utilization of Electrical Energy- 1 - Question 11

Trapezoidal speed-time curve pertains to:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 11

Main line services: The distance between two stops is usually more than 10 km. High balancing speeds should be required. Acceleration and retardation are not so important

Urban service: The distance between two stops is very less and it is less than 1 km. It requires high average speed for frequent starting and stopping

Sub urban service: The distance between two stops is between 1 km and 8 km. This service requires rapid acceleration and retardation as frequent starting and stopping is required

In main line service, free running period is more. Hence Trapezoidal speed-time curve pertains to main line service

Test: Utilization of Electrical Energy- 1 - Question 12

For a given value of an average speed, decrease in duration of stops causes:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 12

Average Speed: It is the mean of the speeds attained by the train from start to stop, i.e. it is defined as the ratio of the distance covered by the train between two stops to the total time of run. It is denoted with Va

Average speed = distance between stops / actual time of run

Va = D/T

Where Vis the average speed of train in kmph

D is the distance between stops in km

T is the actual time in hours

Schedule Speed: The ratio of the distance covered between two stops to the total time of the run including the time for stop is known as schedule speed. It is denoted with Vs


Where Ts is the schedule time in hours

For a given value of an average speed, decrease in duration of stops causes increase in schedule speed

Test: Utilization of Electrical Energy- 1 - Question 13

The most modern method for the food processing is:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 13

Dielectric heating has been applied in the food processing industry:

1. Dehydrating fruits, vegetables, eggs etc.

2. Cooking food without removing the outer shells

3. Pasteurizing milk and beer inside bottles

4. Defrosting frozen foods in large bakeries and restaurants

Test: Utilization of Electrical Energy- 1 - Question 14

The furnaces used for cremation are:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 14

Electric resistance heating furnace is used for cremation purpose

Test: Utilization of Electrical Energy- 1 - Question 15

The power factor will be maximum in case of:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 15

The power factor will be maximum in case of resistance heating compared to any other heating method

Test: Utilization of Electrical Energy- 1 - Question 16

The dielectric loss in a dielectric is proportional to:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 16

Dielectric loss is

PL= V2ωCδPL = V2ωCδ

Where, V is the applied voltage in V

f is the supply frequency in Hz

C is the capacitance

δ is the loss angle in radian

Dielectric loss is directly proportional to the square of the voltage impressed on the dielectric

Test: Utilization of Electrical Energy- 1 - Question 17

The supply frequency usually employed for high frequency eddy current heating is:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 17

The supply frequency usually employed for high frequency eddy current heating is 10-400 kHz

The supply frequency usually employed for dielectric heating is 1-40 MHz

Test: Utilization of Electrical Energy- 1 - Question 18

The luminous flux is measured in:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 18

Test: Utilization of Electrical Energy- 1 - Question 19

The process of providing an oxide film is known as:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 19

Electrodeposition: It is the process by which one metal is deposited over other metal or non-metal by electrolysis

Electro metallization: It is the process by which the metal can be deposited on a conduction base for decoration and for protective purposes. Any non-conductive base is made as conductive by depositing graphite layer over it

Electro facing: It is the process of the coating of a metallic surface with a harder metal by electrodeposition

Anodizing: The process of deposition of oxide film on a metal surface is known as anodizing and oxidation

Test: Utilization of Electrical Energy- 1 - Question 20

The filtration of electrolyte is necessary:

Detailed Solution for Test: Utilization of Electrical Energy- 1 - Question 20

The filtration of electrolyte is necessary to remove the suspended salt particles and the other suspended impurities from the electrolyte

Information about Test: Utilization of Electrical Energy- 1 Page
In this test you can find the Exam questions for Test: Utilization of Electrical Energy- 1 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Utilization of Electrical Energy- 1, EduRev gives you an ample number of Online tests for practice

Top Courses for Electrical Engineering (EE)

Download as PDF