Test: D.C Machines & Transformers - 2 for Electrical Engineering (EE) 2024 is part of Electrical Engineering (EE) preparation. The Test: D.C Machines & Transformers - 2 questions and answers have been prepared according to the Electrical Engineering (EE) exam syllabus.The Test: D.C Machines & Transformers - 2 MCQs are made for Electrical Engineering (EE) 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: D.C Machines & Transformers - 2 below.
Solutions of Test: D.C Machines & Transformers - 2 questions in English are available as part of our course for Electrical Engineering (EE) & Test: D.C Machines & Transformers - 2 solutions in Hindi for Electrical Engineering (EE) course. Download more important topics, notes, lectures and mock test series for Electrical Engineering (EE) Exam by signing up for free. Attempt Test: D.C Machines & Transformers - 2 | 25 questions in 50 minutes | Mock test for Electrical Engineering (EE) preparation | Free important questions MCQ to study for Electrical Engineering (EE) Exam | Download free PDF with solutions
Test: D.C Machines & Transformers - 2 - Question 1

A cumulatively compounded long shunt motor isdriving a load at rated torque and rated speed.If the series field is shunted by a resistance equalto the resistance of the series field keeping the torque constant,

Test: D.C Machines & Transformers - 2 - Question 2

The efficiency of a power transformer is around

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: D.C Machines & Transformers - 2 - Question 3

When voltage is transformed from primary to secondary then it is _____.

Test: D.C Machines & Transformers - 2 - Question 4

If the applied voltage to a transformer primary isincreased by keeping the V/f ratio fixed, then the magnetizing current and the core loss will,respectively:

Test: D.C Machines & Transformers - 2 - Question 5

The applied voltage of a certain transformer isincreased by 75%; while the frequency of the applied voltage is reduced by 25%. The maximum core flux density will :

Test: D.C Machines & Transformers - 2 - Question 6

On no-load phasor diagram of transformer, thecore loss component of the current remains in phase with

Test: D.C Machines & Transformers - 2 - Question 7

At which condition of the transformer theequivalent circuit will be as shown in the figure ?

Test: D.C Machines & Transformers - 2 - Question 8

In a transformer, zero voltage regulation at full load s:

Test: D.C Machines & Transformers - 2 - Question 9

While performing the open-circuit and shortcircuit tests on a transformer to determine parameters the status of the low voltage (LV) and high voltage (HV) windings will be such that

Test: D.C Machines & Transformers - 2 - Question 10

A 2 kVA transformer has iron loss of 150 Wand full-load copper loss of 250 W. Themaximum efficiency of the transformer wouldoccur when the total loss is

Test: D.C Machines & Transformers - 2 - Question 11

Grain oriented laminated sheet steel intransformer reduces

Test: D.C Machines & Transformers - 2 - Question 12

The colour of fresh dielectric oil used intransformers is

Test: D.C Machines & Transformers - 2 - Question 13

Transformer oil must be free from

Test: D.C Machines & Transformers - 2 - Question 14

Conservator (for transformer) is used

Test: D.C Machines & Transformers - 2 - Question 15

The noise, in a transformer, caused by vibrationsof laminations set by magnetic forces, is termed as

Test: D.C Machines & Transformers - 2 - Question 16

Distribution transformers have core losses

Test: D.C Machines & Transformers - 2 - Question 17

In Scott connection, if the turns ratio of main transformer is K,

Test: D.C Machines & Transformers - 2 - Question 18

The copper loss is constant for

Test: D.C Machines & Transformers - 2 - Question 19

Current-versus time graph for an idealcommutation is a

Test: D.C Machines & Transformers - 2 - Question 20

The dummy coils in d.c. machines re useful to

Test: D.C Machines & Transformers - 2 - Question 21

In a series wound d.c. machine (generator ormotor), the series field winding consists of

Test: D.C Machines & Transformers - 2 - Question 22

A d.c. shunt motor takes 5A at 100 V whenrunning light. shunt field resistance is 50W and armature resistance is 0.2W. What is the driving power ?

Test: D.C Machines & Transformers - 2 - Question 23

If the applied voltage to a dc machine is 230 V, then the back emf, for maximum power developed, is

Test: D.C Machines & Transformers - 2 - Question 24

The armature resistance of a 6-pole lap woundgenerator is 0.05W. If the armature is rewoundusing a wave winding, the armature resistancewill be

Test: D.C Machines & Transformers - 2 - Question 25

A 4-pole, 500 V shunt motor has 720 wave connected conductors on its armature. The fullloadarmature current is 60 A and flux per poleis 0.03 Wb. The armature resistance is 0.2Wand contact drop per brush is 1V. What is the back e.m.f ?