Test: Power Systems - 2 for Electrical Engineering (EE) 2024 is part of Electrical Engineering (EE) preparation. The Test: Power Systems - 2 questions and answers have been prepared according to the Electrical Engineering (EE) exam syllabus.The Test: Power Systems - 2 MCQs are made for Electrical Engineering (EE) 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Power Systems - 2 below.
Solutions of Test: Power Systems - 2 questions in English are available as part of our course for Electrical Engineering (EE) & Test: Power Systems - 2 solutions in Hindi for Electrical Engineering (EE) course. Download more important topics, notes, lectures and mock test series for Electrical Engineering (EE) Exam by signing up for free. Attempt Test: Power Systems - 2 | 25 questions in 50 minutes | Mock test for Electrical Engineering (EE) preparation | Free important questions MCQ to study for Electrical Engineering (EE) Exam | Download free PDF with solutions
Test: Power Systems - 2 - Question 1

As per IE rule, if the leakage current in an electrical installation exceeds a specified value, no supply should be given until the cause of the same is removed, this specified value is 1/5000 the part of ...............

Test: Power Systems - 2 - Question 2

Which material is having negative temperature coefficient ?

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Power Systems - 2 - Question 3

As per BIS rule the resistance of earth electrode should be measured in ............... weather.

Test: Power Systems - 2 - Question 4

A choke is generally used in series with the tube in a fluorescent lamp circuit to

Test: Power Systems - 2 - Question 5

In a power house, illumination should be approximately ............

Test: Power Systems - 2 - Question 6

Power factor of an alternator driven by constant prime mover input can be changed by changing its

Test: Power Systems - 2 - Question 7

The restraining voltage is measured in

Test: Power Systems - 2 - Question 8

Where is the draft tube of a hydropower station that is an airtight pipe located ?

Test: Power Systems - 2 - Question 9

What is the nominal pH value of water that is to be maintained in a steam raising thermal power station ?

Test: Power Systems - 2 - Question 10

The maximum demand of a consumer is 2 kW and the corresponding daily energy consumption is 30 unit. What is the corresponding load factor ?

Test: Power Systems - 2 - Question 11

Buses for load flow studies are classified as (i)the load bus, (ii) the generator bus and (iii) the
slack bus The correct combination of the pair of quantities specified having their usual meaning for different buses is

Test: Power Systems - 2 - Question 12

The impedance value of generator is 0.2 pu on a base value of 11 kV, 50 MVA. The impedance value for a base value of 22 KV, 150 MVA is

Test: Power Systems - 2 - Question 13

If the fault current is 2 kA, the relay setting is 50% and the C.T. ratio is 400/5, then the plug setting multiplier of a relay will be

Test: Power Systems - 2 - Question 14

A power plant has a maximum demand of 15 MW. The load factor is 50% and the plant factor is 40%. The operating reserve is

Test: Power Systems - 2 - Question 15

The load curve of system is shown in the figure.

The load factor of the system is

Test: Power Systems - 2 - Question 16

Galloping in transmission line conductors arises generally due to

Detailed Solution for Test: Power Systems - 2 - Question 16

Galloping is a low frequency, large amplitude, wind-induced vibration of both single and bundle overhead conductors, with a single or a few loops of standing waves per span. It is caused by moderately strong, steady crosswind acting upon an asymmetrically- iced conductor surface.

Test: Power Systems - 2 - Question 17

A thermal generating station has an installed capacity of 15 MW and supplies a daily load of 10 MW for 12 hours and 5 MW of remaining 12 hours. The plant capacity factor for this station is

Detailed Solution for Test: Power Systems - 2 - Question 17

Plant capacity factor =

average energy produced/maximum possible energy based on installed capacity

= 10 x12 + 5 x 12 / 24 x 15 = 0.5

Test: Power Systems - 2 - Question 18

Compared to Gauss-seidel method, Newton- Raphson method takes

Test: Power Systems - 2 - Question 19

The operation of a nuclear reactor is controlled by controlling multipliction factor (K) defined as

The power -level of the reactor can be increased by

Test: Power Systems - 2 - Question 20

Non-metallic conduits used in internal wiring are generally made of

Test: Power Systems - 2 - Question 21

PVC cables are usually used for

Test: Power Systems - 2 - Question 22

The rating of fuse wire is always expressed in

Test: Power Systems - 2 - Question 23

Protection by fuses is generally not used beyond

Test: Power Systems - 2 - Question 24

Energy meter, for connecting, has ––––––– terminals.

Detailed Solution for Test: Power Systems - 2 - Question 24

Correct Answer :- b

Explanation : An energy meter usually has four terminals. A pair of terminals for the current coil and another pair for the Voltage coil (a.k.a pressure coil). As their name suggests, current coil is in series with the line and or produces magnetic field according to the current flow.

Whereas Voltage coil is in parallel with the Load and it produces magnetic field according to the voltage drop across the Load.

These two fields combine to produce a torque which rotates the aluminum disc on a conventional Energy meter.

Test: Power Systems - 2 - Question 25

The positive sequence current for a L-L fault of a 2 kV system is 1400 A, and corresponding current for a L-L-G fault is 2220 A. The zero sequence impedance of the system is

Information about Test: Power Systems - 2 Page
In this test you can find the Exam questions for Test: Power Systems - 2 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Power Systems - 2, EduRev gives you an ample number of Online tests for practice

Top Courses for Electrical Engineering (EE)

Download as PDF

Top Courses for Electrical Engineering (EE)