Electrical Engineering (EE) Exam  >  Electrical Engineering (EE) Tests  >  Test: Power Systems - 7 - Electrical Engineering (EE) MCQ

Test: Power Systems - 7 - Electrical Engineering (EE) MCQ


Test Description

25 Questions MCQ Test - Test: Power Systems - 7

Test: Power Systems - 7 for Electrical Engineering (EE) 2024 is part of Electrical Engineering (EE) preparation. The Test: Power Systems - 7 questions and answers have been prepared according to the Electrical Engineering (EE) exam syllabus.The Test: Power Systems - 7 MCQs are made for Electrical Engineering (EE) 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Power Systems - 7 below.
Solutions of Test: Power Systems - 7 questions in English are available as part of our course for Electrical Engineering (EE) & Test: Power Systems - 7 solutions in Hindi for Electrical Engineering (EE) course. Download more important topics, notes, lectures and mock test series for Electrical Engineering (EE) Exam by signing up for free. Attempt Test: Power Systems - 7 | 25 questions in 50 minutes | Mock test for Electrical Engineering (EE) preparation | Free important questions MCQ to study for Electrical Engineering (EE) Exam | Download free PDF with solutions
Test: Power Systems - 7 - Question 1

Match List-I with List-II and select the correct answer using the codes given below the lists:

Test: Power Systems - 7 - Question 2

Consider the following statement :
1. The insulation resistance of cable will increase if the length of the cable is increased
2. For the same overall diameter of cable, the grading of cable will increases the safe working voltage
3. The normal operating temperature of PVC cable is 70ºC
4. The thermal resistance of soil increase as the moisture content of soil increase
Of these statement

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Power Systems - 7 - Question 3

Consider the following for line conductors:
1. Hard drawn copper
2. Cadmium copper
3. Aluminum
4. Galvanized steel
The correct sequence of the descending order of their electrical conductivities is

Test: Power Systems - 7 - Question 4

Lighting arresters are used in power systems to protect electrical equipments against

Test: Power Systems - 7 - Question 5

The voltages across the various discs of a string of suspension insulators having identical discs is different due to

Test: Power Systems - 7 - Question 6

A Bucholz relay is used for

Test: Power Systems - 7 - Question 7

To prevent maloperation of differentially relay while energizing a transformer, the relay restraining coil is biased with

Test: Power Systems - 7 - Question 8

In a medium or high head hydroelectric power station, a surge tank is provided to

Test: Power Systems - 7 - Question 9

Transmission lines are transported to

Test: Power Systems - 7 - Question 10

The impedance value of generator is 0.2 pu on a base value of 11 kV, 50 MVA. The impedance value for a base value of 22 KV, 150 MVA is

Test: Power Systems - 7 - Question 11

A surge voltage of 1000 kV is applied to an overhead line with its receiving -end open. If the surge impedance of the line is 500W, then the total surge power in the line is

Test: Power Systems - 7 - Question 12

Impulse ratio of insulators and lightning arresters should be

Test: Power Systems - 7 - Question 13

Bundled conductors in EHV transmission system provide

Test: Power Systems - 7 - Question 14

The charging current in a transmission line increases due to corona effect because corona increases

Test: Power Systems - 7 - Question 15

If the fault current is 2 kA, the relay setting is 50% and the C.T. ratio is 400/5, then the plug setting multiplier of a relay will be

Test: Power Systems - 7 - Question 16

The load curve of system is shown in the figure.

The load factor of the system is

Test: Power Systems - 7 - Question 17

Control rods used in neuclear reactors are made of

Test: Power Systems - 7 - Question 18

In a 3-core extra-high voltage cable, a metallic screen around each core-insulation is provided to

Test: Power Systems - 7 - Question 19

Galloping in transmission line conductors arises generally due to

Test: Power Systems - 7 - Question 20

Hollow conductors are used in transmission line to

Test: Power Systems - 7 - Question 21

Zero sequence current can flow from a line into a transformer bank if the windings are in

Test: Power Systems - 7 - Question 22

When a line-to-ground fault occurs, the current in a faulted phase is 100 A. The zero sequence current in this case will be

Test: Power Systems - 7 - Question 23

"Expanded ACSR" are conductors composed of

Test: Power Systems - 7 - Question 24

The non-uniform distribution of voltage across the units in a string of suspension type insulators is due to

Test: Power Systems - 7 - Question 25

Whenever the conductors are dead-ended or there is a change in the direction of transmission line, the insulators used are of the

Information about Test: Power Systems - 7 Page
In this test you can find the Exam questions for Test: Power Systems - 7 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Power Systems - 7, EduRev gives you an ample number of Online tests for practice

Top Courses for Electrical Engineering (EE)

Download as PDF

Top Courses for Electrical Engineering (EE)