Electrical Engineering (EE) Exam  >  Electrical Engineering (EE) Tests  >  Test: Power Systems - 8 - Electrical Engineering (EE) MCQ

Test: Power Systems - 8 - Electrical Engineering (EE) MCQ


Test Description

25 Questions MCQ Test - Test: Power Systems - 8

Test: Power Systems - 8 for Electrical Engineering (EE) 2024 is part of Electrical Engineering (EE) preparation. The Test: Power Systems - 8 questions and answers have been prepared according to the Electrical Engineering (EE) exam syllabus.The Test: Power Systems - 8 MCQs are made for Electrical Engineering (EE) 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Power Systems - 8 below.
Solutions of Test: Power Systems - 8 questions in English are available as part of our course for Electrical Engineering (EE) & Test: Power Systems - 8 solutions in Hindi for Electrical Engineering (EE) course. Download more important topics, notes, lectures and mock test series for Electrical Engineering (EE) Exam by signing up for free. Attempt Test: Power Systems - 8 | 25 questions in 50 minutes | Mock test for Electrical Engineering (EE) preparation | Free important questions MCQ to study for Electrical Engineering (EE) Exam | Download free PDF with solutions
Test: Power Systems - 8 - Question 1

Consider the following statements: In the case of suspension-type insulators, the string efficiency can be improved by
1. Using a longer cross-arm
2. Using a guard ring.
3. Grading the insulator discs
4. Reducing the cross-arm length
Of these statements

 

Test: Power Systems - 8 - Question 2

Match List-I (Type of relay) with List-II (For the protection of) and select the correct answer using the given below the lists:

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Power Systems - 8 - Question 3

In connection with arc the extinction in circuit breaker, resistance switching is employed where in a resistance is placed in parallel with the poles of the circuit breaker as shown in the figure. This process introduces damping in the LC circuit. For critical damping, the value of 'R' should be equal to

Test: Power Systems - 8 - Question 4

Consider the following moderators used in nuclear reactors:
1. Graphite 2. Beryllium
3. Heavy water
Their correct sequence in increasing order of their neutron absorption cross sections is

Test: Power Systems - 8 - Question 5

Match List-I with List-II and select the correct answer using the given below the lists:

Test: Power Systems - 8 - Question 6

lighting arrestor connected between the line and earth in a power system

Detailed Solution for Test: Power Systems - 8 - Question 6

Lightning arresters or surge diverters:

  • A lightning arrester or a surge diverter is a protective device which conducts the high voltage surges on the power system to the ground
  • It consists of a spark gap in series with a non-linear resistor
  • The length of the gap is so set that normal line voltage is not enough to cause an arc across the gap, but a dangerously high voltage will break down the air insulation and form an arc
  • The property of the non-linear resistance is that its resistance decreases as the voltage (or current) increases and vice-versa
  • One end of the diverter is connected to the terminal of the equipment to be protected and the other end is effectively grounded
Test: Power Systems - 8 - Question 7

Corona loss can be reduced by the use of follow conductors, because

Test: Power Systems - 8 - Question 8

The insulation of modern EHV lines is designed based on

Test: Power Systems - 8 - Question 9

While using air-blast circuit beaker, current chopping is a phenomenon often observed when

Test: Power Systems - 8 - Question 10

In a power station the cost of generation of power reduces most effectively when

Test: Power Systems - 8 - Question 11

Shunt compensation in an EHV line is used to

Test: Power Systems - 8 - Question 12

In pumped storage scheme, the generator is also used us

Test: Power Systems - 8 - Question 13

Consider the following statement: Distance relays used for protection of transmission line might operate undesirable due to
1. magnetizing-current in rush
2. Power swings
3. Series compensating capacitors
4. Switching over voltage
Of these statements

Test: Power Systems - 8 - Question 14

The number of discs in a string of insulators for 400 kV ac overhead transmission line lies in the range of

Test: Power Systems - 8 - Question 15

The insulation resistance of a single -core cable is 200 MW/ km.The insulation resistance for 5 km length is

Test: Power Systems - 8 - Question 16

Consider the following statements:
1. By using bundle conductors is an overhead line, the corona loss is reduced
2. By using bundle conductors, the inductance of transmission line increase and capacitance reduces.
3. Corona loss causes interference in adjoining communication lines.
What of these statement are correct ?

Test: Power Systems - 8 - Question 17

Which one of the following sequences of operation represents the rated operating duty cycle of a circuit breaker? (O-open; C-close; t= 3 sec; T=3min)

Test: Power Systems - 8 - Question 18

A2-phase circuit breaker is rated at 2000 MVA. 33kV; its making current will be

Test: Power Systems - 8 - Question 19

The most accurate and versatile method of achieving reactive power compensation is by using

Test: Power Systems - 8 - Question 20

If the positive, negative and zero-sequence reactance's of an element of a power system are 0.3, 0.3 and 0.8 respectively, then the element would be a

Test: Power Systems - 8 - Question 21

Disruptive corona begins in smooth cylindrical conductors in air at NTP if the electric field intensity at the conductor surface goes up to

Test: Power Systems - 8 - Question 22

Load flow studies involve solving simultaneous

Test: Power Systems - 8 - Question 23

If the inductance and capacitance of power system are respectively 1 H and 0.01mF and the instantaneous value of interrupted current is 10 A, then the voltage across the breaker contact will be

Test: Power Systems - 8 - Question 24

For successful parallel operation of two singlephase transformers, the most essential condition is that their

Test: Power Systems - 8 - Question 25

Arrange the following in the correct sequence in which the flue gas passes through them after coming out of the boiler in thermal power station:

1. I.D. Fan.

2. Air Preheater

3. Economizer

4. Electrostatic precipitator

Select the correct answer using the codes given below:Codes:

Information about Test: Power Systems - 8 Page
In this test you can find the Exam questions for Test: Power Systems - 8 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Power Systems - 8, EduRev gives you an ample number of Online tests for practice

Top Courses for Electrical Engineering (EE)

Download as PDF

Top Courses for Electrical Engineering (EE)