Chemical Engineering Exam  >  Chemical Engineering Tests  >  Test: Continuous Operation Of Distillation Column - Chemical Engineering MCQ

Test: Continuous Operation Of Distillation Column - Chemical Engineering MCQ


Test Description

10 Questions MCQ Test - Test: Continuous Operation Of Distillation Column

Test: Continuous Operation Of Distillation Column for Chemical Engineering 2024 is part of Chemical Engineering preparation. The Test: Continuous Operation Of Distillation Column questions and answers have been prepared according to the Chemical Engineering exam syllabus.The Test: Continuous Operation Of Distillation Column MCQs are made for Chemical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Continuous Operation Of Distillation Column below.
Solutions of Test: Continuous Operation Of Distillation Column questions in English are available as part of our course for Chemical Engineering & Test: Continuous Operation Of Distillation Column solutions in Hindi for Chemical Engineering course. Download more important topics, notes, lectures and mock test series for Chemical Engineering Exam by signing up for free. Attempt Test: Continuous Operation Of Distillation Column | 10 questions in 20 minutes | Mock test for Chemical Engineering preparation | Free important questions MCQ to study for Chemical Engineering Exam | Download free PDF with solutions
Test: Continuous Operation Of Distillation Column - Question 1

 Rectifying continuously is known as _____________

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 1

Explanation: Fractionation is the continuous separation of volatile component.

Test: Continuous Operation Of Distillation Column - Question 2

The top of the fractionators have ______ temperature.

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 2

Explanation: To maintain the dew point we need to have low temperature.

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Continuous Operation Of Distillation Column - Question 3

 The section above the feed tray in a fractionator is known as ______________

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 3

Explanation: The enriching section where the low volatile components are absorbed in the liquid condensed.

Test: Continuous Operation Of Distillation Column - Question 4

 

The notation X from the figure below is known as Reflux.

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 4

Explanation: Some part of the condensed product are sent back to the rectifying column for the effective separation is known as reflux.

Test: Continuous Operation Of Distillation Column - Question 5

The bottom of the fractionators have ______ temperature.

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 5

Explanation: To maintain the bubble point we need to have high temperature.

Test: Continuous Operation Of Distillation Column - Question 6

 The section below the feed tray in a fractionator is known as ______________

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 6

Explanation: The rectifying section where the high volatile components are stripped from the liquid condensed.

Test: Continuous Operation Of Distillation Column - Question 7

Express the reflux ratio

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 7

Explanation: The reflux ratio is the ratio of reflux(R) to the Distillate(D).

Test: Continuous Operation Of Distillation Column - Question 8

The use of vapour produced from the reboiler is

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 8

Explanation: The vapour from the stripping section strips the more volatile component to form distillate.

Test: Continuous Operation Of Distillation Column - Question 9

The light key components are__________

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 9

Explanation: Since the light key components have low boiling point it is a more volatile component.

Test: Continuous Operation Of Distillation Column - Question 10

Find the reflux ratio if the feed , residue and reflux rate is 100, 40 and 50 mole/hr.

Detailed Solution for Test: Continuous Operation Of Distillation Column - Question 10

Explanation: Reflux ratio = reflux/distillate
Distillate= 100-40=60
Reflux ratio= 50/60 = 0.83.

Information about Test: Continuous Operation Of Distillation Column Page
In this test you can find the Exam questions for Test: Continuous Operation Of Distillation Column solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Continuous Operation Of Distillation Column, EduRev gives you an ample number of Online tests for practice
Download as PDF