Mechanical Engineering Exam  >  Mechanical Engineering Tests  >  GATE Mechanical (ME) Mock Test Series 2025  >  RAC & I.C. Engine - 1 - Mechanical Engineering MCQ

RAC & I.C. Engine - 1 - Mechanical Engineering MCQ


Test Description

15 Questions MCQ Test GATE Mechanical (ME) Mock Test Series 2025 - RAC & I.C. Engine - 1

RAC & I.C. Engine - 1 for Mechanical Engineering 2024 is part of GATE Mechanical (ME) Mock Test Series 2025 preparation. The RAC & I.C. Engine - 1 questions and answers have been prepared according to the Mechanical Engineering exam syllabus.The RAC & I.C. Engine - 1 MCQs are made for Mechanical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for RAC & I.C. Engine - 1 below.
Solutions of RAC & I.C. Engine - 1 questions in English are available as part of our GATE Mechanical (ME) Mock Test Series 2025 for Mechanical Engineering & RAC & I.C. Engine - 1 solutions in Hindi for GATE Mechanical (ME) Mock Test Series 2025 course. Download more important topics, notes, lectures and mock test series for Mechanical Engineering Exam by signing up for free. Attempt RAC & I.C. Engine - 1 | 15 questions in 60 minutes | Mock test for Mechanical Engineering preparation | Free important questions MCQ to study GATE Mechanical (ME) Mock Test Series 2025 for Mechanical Engineering Exam | Download free PDF with solutions
RAC & I.C. Engine - 1 - Question 1

Air refrigeration cycle is used in

RAC & I.C. Engine - 1 - Question 2

A Carnot refrigeration system requires 1.5 kW per ton of refrigeration to maintain a region at –30° C. The COP of system will be

Detailed Solution for RAC & I.C. Engine - 1 - Question 2

1 Crore+ students have signed up on EduRev. Have you? Download the App
RAC & I.C. Engine - 1 - Question 3

When the Brayton cycle working in the pressure limits of p1 and p2 is reversed and operated as a refrigerator, what is the ideal value of COP for such a cycle? 

Detailed Solution for RAC & I.C. Engine - 1 - Question 3



RAC & I.C. Engine - 1 - Question 4

The refrigerant commonly used in vapour absorption system is

RAC & I.C. Engine - 1 - Question 5

In a lithium Bromide absorption refrigeration system

RAC & I.C. Engine - 1 - Question 6

A cold storage is to be maintained at –5°C while the surroundings are at 35°C. The heat leakage from the surrounding in to cold storage is estimated to be 29 kW. The actual COP of refrigeration plant is one third of an ideal pant working between the same temperature limit. Power required to drive the plant will be

Detailed Solution for RAC & I.C. Engine - 1 - Question 6




RAC & I.C. Engine - 1 - Question 7

A refrigerating machine working on reversed Carnot cycle takes out 2 kW from the system while operating between temperature limits of 300 K and 200 K. COP and power consumed by the cycle will be respectively:

Detailed Solution for RAC & I.C. Engine - 1 - Question 7

*Answer can only contain numeric values
RAC & I.C. Engine - 1 - Question 8

A refrigeration system operating on reversed brayton cycle has a temperature of 250 k at inlet to the compressor. If the temperature at the end of constant pressure cooling is 300 k and rise in temperature of air in refrigerator is 50 k. Then the net work of compression will be _______ kJ/kg (for air cp = 1 kJ/kg K)


Detailed Solution for RAC & I.C. Engine - 1 - Question 8



RAC & I.C. Engine - 1 - Question 9

A vapour absorption refrigeration system works with generator, ambient and evaporator temperature as 360 K, 310 K and 260 K respectively. If the evaporator temperature falls to 250 K what should be the generator temperature in order to operate the system with same COP

Detailed Solution for RAC & I.C. Engine - 1 - Question 9


RAC & I.C. Engine - 1 - Question 10

In aqua ammonia absorption system the heat is supplied to generator by condensing steam at 0.2 MPa and 90% dryness fraction. The temperature to be maintained in refrigeration is –10°C and the ambient temperature is 30°C. The actual COP is the 40% of the maximum COP and the refrigeration effect is 20 TR. The required flow rate will be (Given: at 0.2 MPa saturation, temperature = 120.2°C = 2201.9 kJ/kg)

Detailed Solution for RAC & I.C. Engine - 1 - Question 10


*Answer can only contain numeric values
RAC & I.C. Engine - 1 - Question 11

Maximum possible COP of a solar absorption refrigeration system with generator temperature of 360 K, absorber temperature of 300 K, condenser temperature of 300 K and evaporator temperature of 270 K is ___________.


Detailed Solution for RAC & I.C. Engine - 1 - Question 11

RAC & I.C. Engine - 1 - Question 12

A refrigerator based on ideal vapour compression cycle operates between the temperature limits of –20°C and 40°C. The refrigerant enters the condenser as saturated vapour and leaves as saturated liquid. The enthalpy and entropy values for saturated liquid and vapour at these temperature are given in the table below.

Q. 

If refrigerant circulation rate is 0.025 kg/s, the refrigeration capacity is equal to

Detailed Solution for RAC & I.C. Engine - 1 - Question 12




RAC & I.C. Engine - 1 - Question 13

A refrigerator based on ideal vapour compression cycle operates between the temperature limits of –20°C and 40°C. The refrigerant enters the condenser as saturated vapour and leaves as saturated liquid. The enthalpy and entropy values for saturated liquid and vapour at these temperature are given in the table below.

Q. 

The COP of the refrigerator is 

Detailed Solution for RAC & I.C. Engine - 1 - Question 13

*Answer can only contain numeric values
RAC & I.C. Engine - 1 - Question 14

A vapour absorption refrigeration system is a heat pump with three thermal reservoirs as shown in the figure. A refrigeration effect of 100 W is required at 250 K when the heat source available is at 400 K. Heat rejection occurs at 300 K. The minimum value of heat required (in W) is ___________.


Detailed Solution for RAC & I.C. Engine - 1 - Question 14



RAC & I.C. Engine - 1 - Question 15

Moist air at a pressure of 100 kPa is compressed to 500 kPa and then cooled to 35°C in an aftercooler. The air at the entry to the aftercooler is unsaturated and becomes just saturated at the exit of the aftercooler. The saturation pressure of water at 35°C is 5.628 kPa. The partial pressure of water vapour (in kPa) in the moist air entering the compressor is closest to

Detailed Solution for RAC & I.C. Engine - 1 - Question 15




29 docs|220 tests
Information about RAC & I.C. Engine - 1 Page
In this test you can find the Exam questions for RAC & I.C. Engine - 1 solved & explained in the simplest way possible. Besides giving Questions and answers for RAC & I.C. Engine - 1, EduRev gives you an ample number of Online tests for practice

Top Courses for Mechanical Engineering

Download as PDF

Top Courses for Mechanical Engineering