Mechanical Engineering Exam  >  Mechanical Engineering Tests  >  Thermodynamics  >  Test: Refrigerants - 3 - Mechanical Engineering MCQ

Test: Refrigerants - 3 - Mechanical Engineering MCQ


Test Description

15 Questions MCQ Test Thermodynamics - Test: Refrigerants - 3

Test: Refrigerants - 3 for Mechanical Engineering 2024 is part of Thermodynamics preparation. The Test: Refrigerants - 3 questions and answers have been prepared according to the Mechanical Engineering exam syllabus.The Test: Refrigerants - 3 MCQs are made for Mechanical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Refrigerants - 3 below.
Solutions of Test: Refrigerants - 3 questions in English are available as part of our Thermodynamics for Mechanical Engineering & Test: Refrigerants - 3 solutions in Hindi for Thermodynamics course. Download more important topics, notes, lectures and mock test series for Mechanical Engineering Exam by signing up for free. Attempt Test: Refrigerants - 3 | 15 questions in 45 minutes | Mock test for Mechanical Engineering preparation | Free important questions MCQ to study Thermodynamics for Mechanical Engineering Exam | Download free PDF with solutions
Test: Refrigerants - 3 - Question 1

 Which one of the following refrigerants is an Azeotrope?

Detailed Solution for Test: Refrigerants - 3 - Question 1

Azeotrope refrigerants are designated by R-500 series.
Hence, R-502 will be an Azeotrope.

Test: Refrigerants - 3 - Question 2

The significant advantage of using Ammonia as a refrigerant is its.

Detailed Solution for Test: Refrigerants - 3 - Question 2

Properties of Ammonia Refrigerant:
1. It is a chemical compound of Nitrogen and Hydrogen and under ordinary condition. It is a colourless gas.
2. High latent heat of vaporization at -15°C latent heat of vaporization is 131b kJ/kg.
3. It is poisonous if inhaled in large quantities.
4. It is some what flammable.

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Refrigerants - 3 - Question 3

The recommended material for use with ammonia as a refrigerants is

Detailed Solution for Test: Refrigerants - 3 - Question 3

Ammonia reacts with copper and hence when ammonia is used as a refrigerant copper material is not used.
Generally wrought iron and steel is used.

Test: Refrigerants - 3 - Question 4

Which one eco-friendly refrigerant out of the following is used in many domestic and car air- conditioners now-a-days?

Detailed Solution for Test: Refrigerants - 3 - Question 4

R-134a is known as eco-friendly refrigerant since it does not contain any Cl atom hence it does not lead to Ozone layer depletion.

Test: Refrigerants - 3 - Question 5

What is an Azeotrope?

Detailed Solution for Test: Refrigerants - 3 - Question 5

Azeotrope is a mixture of refrigerants without phase separation.

Test: Refrigerants - 3 - Question 6

The use of refrigerant R-22 for temperatures below -30°C is not recommended due to its

Test: Refrigerants - 3 - Question 7

Hydrogen is used in electrolux refrigeration system so that vapour pressure of ammonia in the evaporator should be

Test: Refrigerants - 3 - Question 8

Which one of the following refrigerants has the highest critical temperature?

Detailed Solution for Test: Refrigerants - 3 - Question 8

Test: Refrigerants - 3 - Question 9

In an absorption type refrigerator, the heat is supplied to NH3 generator by condensing steam at 2 bar and 90% dry. The temperature in the refrigerator is to be maintained at - 5°C. If the refrigeration load is 20 tones and actual COP is 70% of the maximum then mass of steam required per hour is
(Take atmospheric temperature as 30°C saturation temperature of steam at pressure of 2 bar is 120.2°C, hfg at 2 bar is 2201.6 kJ/kg)

Detailed Solution for Test: Refrigerants - 3 - Question 9

Given: TG = 393.2 k, Tc = 303 k,
TE = -5 + 273 = 268 k

actual COP = 0.7 x 1.756 = 1.229
actual heat supplied = Refrigeration load/Actual COP

Assuming that only latent heat of steam is used for heating

Test: Refrigerants - 3 - Question 10

Match List-I (Refrigerant) with List-Il (Application) and select the correct answer using the codes given below the lists:
    List-l          List-II
A. R-11      1. Window type air conditioning system
B. R-12      2. Central air-conditioning system
C. R-22      3. Domestic refrigerator
D. NH3      4. Cold storages, ice plants
Codes:
      A B C D
(a)  2 1  3 4
(b)  4 3  1 2
(c)  2 3  1 4
(d)  4 1  3 2

Detailed Solution for Test: Refrigerants - 3 - Question 10

R - 11: It is used with centrifugal co m pressor in large capacity central air-conditioning plants.
R-12: It is used with reciprocating compressors in small units, specially domestic refrigerators, water coolers etc.
R-22: It is used with reciprocating compressors in window type air conditioners and large units such as package units and central air conditioning plants.
NH3: It is used with reciprocating and screw compressors, in cold storage, i.e., plants, food refrigeration, etc.

Test: Refrigerants - 3 - Question 11

Match List-I (Property of refrigerant or absorbent) with List-II (Name of refrigerant) and select the correct answer using the code given below the lists
List-I                                                                  List-II
A. Used for very low temperature                     1. CF4
B. Used with centrifugal compressors              2. CCI3F
C. Used in vortex tube                                     3. Air
Codes:    A  B  C
          (a) 1  2  3
          (b) 3  1  2
          (c) 1  3  2
          (d) 3  2  1

Test: Refrigerants - 3 - Question 12

When the mixture of refrigerant is used to replace a refrigerant, if the COP increase, the reason attributed is

Detailed Solution for Test: Refrigerants - 3 - Question 12


i.e., cooling effect increases

Test: Refrigerants - 3 - Question 13

Match List-l with List-ll and select the correct answer using the codes given below the lists:
List-l                                     List-ll
A. Sulphur candle test        1. Propane
B. Halide torch test             2. Ammonia
C. Soap and water test       3. Halocarbon refrigerants
D. Ammonia Swab test       4. Sulphur dioxide
Codes:
      A  B   C  D
(a)  2  3   1   4
(b)  4  1   3   2
(c)  2  1   3   4
(d)  4  3   1   2

Test: Refrigerants - 3 - Question 14

Ideal refrigerant mixture is one which

Test: Refrigerants - 3 - Question 15

Consider the following statements:
1. Azeotropes are the mixtures of refrigerants and behave like pure substances.
2. Isomers refrigerants are compounds with the same chemical formula but have different molecular structures.
3. The formula n + p + q = 2m is used for unsaturated chloro-fluorocarbon compounds (m, n, p and q are the number of atoms of carbon, hydrogen, fluorine and chlorine respectively.)
​Q. Which of these statements are correct?

Detailed Solution for Test: Refrigerants - 3 - Question 15

Azeotropes are non ideal mixture as they show deviation from Raoults law.

29 videos|65 docs|36 tests
Information about Test: Refrigerants - 3 Page
In this test you can find the Exam questions for Test: Refrigerants - 3 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Refrigerants - 3, EduRev gives you an ample number of Online tests for practice

Top Courses for Mechanical Engineering

29 videos|65 docs|36 tests
Download as PDF

Top Courses for Mechanical Engineering