Civil Engineering (CE) Exam  >  Civil Engineering (CE) Tests  >  GATE Civil Engineering (CE) 2025 Mock Test Series  >  Test: Sewage Collection From Houses & Buildings - Civil Engineering (CE) MCQ

Test: Sewage Collection From Houses & Buildings - Civil Engineering (CE) MCQ


Test Description

10 Questions MCQ Test GATE Civil Engineering (CE) 2025 Mock Test Series - Test: Sewage Collection From Houses & Buildings

Test: Sewage Collection From Houses & Buildings for Civil Engineering (CE) 2024 is part of GATE Civil Engineering (CE) 2025 Mock Test Series preparation. The Test: Sewage Collection From Houses & Buildings questions and answers have been prepared according to the Civil Engineering (CE) exam syllabus.The Test: Sewage Collection From Houses & Buildings MCQs are made for Civil Engineering (CE) 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Sewage Collection From Houses & Buildings below.
Solutions of Test: Sewage Collection From Houses & Buildings questions in English are available as part of our GATE Civil Engineering (CE) 2025 Mock Test Series for Civil Engineering (CE) & Test: Sewage Collection From Houses & Buildings solutions in Hindi for GATE Civil Engineering (CE) 2025 Mock Test Series course. Download more important topics, notes, lectures and mock test series for Civil Engineering (CE) Exam by signing up for free. Attempt Test: Sewage Collection From Houses & Buildings | 10 questions in 30 minutes | Mock test for Civil Engineering (CE) preparation | Free important questions MCQ to study GATE Civil Engineering (CE) 2025 Mock Test Series for Civil Engineering (CE) Exam | Download free PDF with solutions
Test: Sewage Collection From Houses & Buildings - Question 1

An intercepting trap is provided at the junction of

Detailed Solution for Test: Sewage Collection From Houses & Buildings - Question 1

An intercepting trap is often provided at the junction of a house sewer and a municipal sewer, so as to prevent the entry of the foul gases of the municipal sewer, into the house drainage system.

Test: Sewage Collection From Houses & Buildings - Question 2

A gully trap is provided at the junction of

Detailed Solution for Test: Sewage Collection From Houses & Buildings - Question 2

A gully trap or a gully is often provided at the junction of a room or a roof drain and the other drain coming from bath, kitchen, etc.

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Sewage Collection From Houses & Buildings - Question 3

The pipe in house plumbing, which carries the discharge from sanitary fittings like bath rooms, etc., is called

Detailed Solution for Test: Sewage Collection From Houses & Buildings - Question 3

Soil pipe drains the night soil. Waste pipe drains sullage from baths etc. Anti-siphonage pipe serves as a suction relieving pipe or a vent pipe to protect the water seals of traps.

Test: Sewage Collection From Houses & Buildings - Question 4

Two pipe system of providing building drainage consists of

Detailed Solution for Test: Sewage Collection From Houses & Buildings - Question 4

In this, system, two sets of vertical pipes are laid, i.e., one for draining night soil, and the other for draining sullage. The pipes of the first set carrying night soil are called soil pipes, and the pipes of the second set carrying sullage from baths etc., are called sullage pipes or waste pipes. The soil pipe as well as the waste pipe, are separately ventilated by providing separate vent pipes or anti siphonage pipes.

Test: Sewage Collection From Houses & Buildings - Question 5

Point out the incorrect statement, in connection with building drainage

Detailed Solution for Test: Sewage Collection From Houses & Buildings - Question 5

Test: Sewage Collection From Houses & Buildings - Question 6

Match List-I with List-lI and select the correct answer using the codes given below the lists: 
List-I
A. Soil pipe
B. Intercepting trap
C. P-trap
D. Cowl

List-II 
1. Ventilating pipe
2. Wash basin
3. Water closet waste
4. House drainage

Codes:
    A B C D
(a) 3 4 1 2
(b) 3 4 2 1
(c) 4 3 2 1
(d) 4 3 1 2

Detailed Solution for Test: Sewage Collection From Houses & Buildings - Question 6

Test: Sewage Collection From Houses & Buildings - Question 7

Which one of the following would help prevent the escape of foul sewer gases from a water closet?

Detailed Solution for Test: Sewage Collection From Houses & Buildings - Question 7

Gully trap is provided at the junction of the room or a roof drain and the other drain coming from bath, kitchen, etc. It may be P-trap or S-trap. Intercepting trap is provided at the junction of a house sewer and a municipal sewer.
Water closets are fitted with P or S-trap.,

Test: Sewage Collection From Houses & Buildings - Question 8

The trap used for a water closet is called

Test: Sewage Collection From Houses & Buildings - Question 9

Soil pipe in plumbing services means a pipe

Test: Sewage Collection From Houses & Buildings - Question 10

Match List-I (Type of waste) with List-ll (Description) and select the correct answer using the codes given below the lists:
List-I
A. Refuse
B. Sullage
C. Sewage
D. Rubbish
List-II
1. Wastes of combustible nature
2. Waste water with higher decomposable fraction
3. All kinds of wastes
4. Waste water with low biodegradable fraction

Detailed Solution for Test: Sewage Collection From Houses & Buildings - Question 10

Rubbish includes combustible and non-combustible solid wastes.

31 docs|280 tests
Information about Test: Sewage Collection From Houses & Buildings Page
In this test you can find the Exam questions for Test: Sewage Collection From Houses & Buildings solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Sewage Collection From Houses & Buildings, EduRev gives you an ample number of Online tests for practice

Top Courses for Civil Engineering (CE)

Download as PDF

Top Courses for Civil Engineering (CE)