Test: Standard Penetration for Civil Engineering (CE) 2024 is part of Foundation Engineering preparation. The Test: Standard Penetration questions and answers have been prepared according to the Civil Engineering (CE) exam syllabus.The Test: Standard Penetration MCQs are made for Civil Engineering (CE) 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Standard Penetration below.
Solutions of Test: Standard Penetration questions in English are available as part of our Foundation Engineering for Civil Engineering (CE) & Test: Standard Penetration solutions in Hindi for Foundation Engineering course. Download more important topics, notes, lectures and mock test series for Civil Engineering (CE) Exam by signing up for free. Attempt Test: Standard Penetration | 10 questions in 30 minutes | Mock test for Civil Engineering (CE) preparation | Free important questions MCQ to study Foundation Engineering for Civil Engineering (CE) Exam | Download free PDF with solutions
Test: Standard Penetration - Question 1

The two commonly used penetration tests are ______

Detailed Solution for Test: Standard Penetration - Question 1

According to Indian standard, the two commonly used penetration tests are static cone penetration test and standard penetration test.

Test: Standard Penetration - Question 2

The standard penetration test is useful to measure

Detailed Solution for Test: Standard Penetration - Question 2

Standard Penetration Test (SPT):

  • It is specially used for cohesionless soils. It is used to determine the relative density and the angle of shearing resistance of cohesionless soils.
  • It can also be used to determine the unconfined compressive strength of cohesive soils.
  • The standard penetration number is equal to the number of blows required for 300 mm of penetration beyond a seating drive of 150 mm.
  • If the number of blows for 150 mm drive exceeds 50, it is taken as refusal and the test is discontinued.
  • Hence the standard penetration test is useful to measure the angle of shearing resistance of cohesionless soils, i.e Shear strength of sands.

Important Points
Some of the other methods for in-situ site exploration are

  • Pressure Meter Test (PMT)
  • Static Cone Penetration Test (SCPT)
  • Vane Shear Test (VST)
1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Standard Penetration - Question 3

The values derived from penetration tests can be used for finding ____________

Detailed Solution for Test: Standard Penetration - Question 3

The penetration test are useful for general exploration of erratic soil profiles, for finding depth to bed rock or hard stratum, and to have an approximation indication of the strength and other properties of soils.

Test: Standard Penetration - Question 4

Correction for increasing effective overburden pressure have been proposed by ___________

Detailed Solution for Test: Standard Penetration - Question 4

For a constant density index, the N value increase with increasing effective overburden pressure for which correction have been proposed by Gibbs and Holtz, peck, Thornburn, Whitman and others.

Test: Standard Penetration - Question 5

The total blow required for the second and third 15 cm of penetration in standard penetration test is taken as ____________

Detailed Solution for Test: Standard Penetration - Question 5

In standard penetration test, the first 15 cm of drive may be considered to be a seating drive. The total blows required for the second and third 15 cm of penetration is termed as the penetration resistance N.

Test: Standard Penetration - Question 6

The cone test is useful in determining the bearing capacity of ___________

Detailed Solution for Test: Standard Penetration - Question 6

The cone test is considered very useful in determining the bearing capacity of pits in cohesion less soils, particularly in fine sands of varying density.

Test: Standard Penetration - Question 7

The observed value of N in static cone penetration test is corrected by _________

Detailed Solution for Test: Standard Penetration - Question 7

The N-value for cohesion less soil shall be corrected for overburden and the values N0 obtained after overburden correction is corrected further for dilatancy.

Test: Standard Penetration - Question 8

The split tube used in static cone penetration test, is commonly known as ______________

Detailed Solution for Test: Standard Penetration - Question 8

The split tube sampler, used in a test for standard penetration is commonly known as split spoon sampler resting on the bottom of the bore hole which is allowed to sink under its own weight.

Test: Standard Penetration - Question 9

The expression for C n as given by Lio and Whitman is _____________

Detailed Solution for Test: Standard Penetration - Question 9

In 1986, Lio and Whitman gave the following expression for
Normalizing factor C n:
C n = √ (100/σ’).

Test: Standard Penetration - Question 10

The cone resistance qc, for sandy silt type of soil is __________

Detailed Solution for Test: Standard Penetration - Question 10

For silts, sandy silts, slightly cohesive silt sand mixture type of soil, the cone resistance q c is 2.