Mechanical Engineering Exam  >  Mechanical Engineering Tests  >  GATE Mechanical (ME) Mock Test Series 2025  >  Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Mechanical Engineering MCQ

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Mechanical Engineering MCQ


Test Description

30 Questions MCQ Test GATE Mechanical (ME) Mock Test Series 2025 - Test: Dimensional & Model Analysis, Centrifugal Pump - 2

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 for Mechanical Engineering 2024 is part of GATE Mechanical (ME) Mock Test Series 2025 preparation. The Test: Dimensional & Model Analysis, Centrifugal Pump - 2 questions and answers have been prepared according to the Mechanical Engineering exam syllabus.The Test: Dimensional & Model Analysis, Centrifugal Pump - 2 MCQs are made for Mechanical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 below.
Solutions of Test: Dimensional & Model Analysis, Centrifugal Pump - 2 questions in English are available as part of our GATE Mechanical (ME) Mock Test Series 2025 for Mechanical Engineering & Test: Dimensional & Model Analysis, Centrifugal Pump - 2 solutions in Hindi for GATE Mechanical (ME) Mock Test Series 2025 course. Download more important topics, notes, lectures and mock test series for Mechanical Engineering Exam by signing up for free. Attempt Test: Dimensional & Model Analysis, Centrifugal Pump - 2 | 30 questions in 90 minutes | Mock test for Mechanical Engineering preparation | Free important questions MCQ to study GATE Mechanical (ME) Mock Test Series 2025 for Mechanical Engineering Exam | Download free PDF with solutions
Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 1

Common Data Question
A centrifugal pump has an efficiency of 80%. The specifications of the pump are:
Discharge = 70 m3/hr, head = 7 m, speed = 1450 rmp and diameter = 2000 mm. If the speed of this pump is increased to 1750 rpm.

Q. Discharge and head developed are given respectively:  

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 1

Ans. (a)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 2

Common Data Question
A centrifugal pump has an efficiency of 80%. The specifications of the pump are:
Discharge = 70 m3/hr, head = 7 m, speed = 1450 rmp and diameter = 2000 mm. If the speed of this pump is increased to 1750 rpm.

Q. Power input required is given by:  

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 2

Ans. (a)

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 3

The following is the arrangement of rotary pumps in descending orderof specific speed at their best efficiency: 

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 3

Ans. (c)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 4

Which one of the following is correct?  
In positive displacement pumps, the slip can sometimes be negativewhen the actual discharge is greater than the theoretical discharge.This happens in

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 4

Ans. (c)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 5

Assertion (A): The efficiency of a pump is generally less than that of aturbine.  
Reason (R): Although the losses in the two types of machines are of the same kind, the losses in pumps are more due to eddy and turbulence.

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 5

Ans. (a) The order of efficiency in pump is 65% but in turbine efficiency is about to
90%. Assertion A is correct. Pump is against nature that so why efficiency is
low.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 6

When the specific speed of the pump is <2600, the type of pump is

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 6

The specific speed of the pump is given by NS = NQ 1/2 / H3/4 and when NS > 2600, the type of pump is centrifugal pump.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 7

Centrifugal pumps have which of the following advantages?  
1. Low initial cost
2. Compact, occupying less floor space
3. Easy handling of highly viscous fluids
Select the correct answer using the code given below:

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 7

Ans. (a) Centrifugal pumps has low initial cost and low maintenance cost that so
why it is widely used.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 8

A centrifugal pump driven by a directly coupled 3 kW motor of 1450rpm speed is proposed to be connected to another motor of 2900 -rpmspeed. The power of the motor should be: 

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 8

Ans. (d)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 9

Which one of tile following statements is correct? 
When a fluid passes from tile inlet to exit of the rotor in a cerltrlfuga1pump, tangential momentum

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 9

Ans. (a) Through the rotor we are adding energy to the fluid therefore energy
cannot remains unchanged.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 10

Which one of the following types of impeller vanes are most commonlyused in centrifugal type compressors?  

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 10

Ans. (b) The blades of the compressor or either forward curved or backward curved or radial. Backward curved blades were used in the older compressors, whereas the modern centrifugal compressors use mostly radial blades.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 11

A centrifugal pump is started with its delivery valve kept  

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 11

Ans. (b) A centrifugal pump is started with delivery valve fully closed.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 12

An aeroplane is cruising at a speed of 800 kmph at altitude, where theair temperature is 0° C. The flight Mach number at this speed is nearly 

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 12

Ans. (c)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 13



Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 13

Ans. (c)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 14

The time period of a simple pendulum depends on its effective length Iand the local acceleration due to gravity g. What is the number of dimensionless parameter involved?  

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 14

Ans. (b) m = 3 (time period, length and acceleration due to gravity); n = 2 (length
and time). Then the number of dimensionless parameter = m – n.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 15

Match List-I (Flow/Wave) with List-II (Dimensionless number) and select the correct answer:  

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 15

Ans. (d)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 16

List-I gives 4 dimensionless numbers and List-II gives the types of forces which are one of the constituents describing the numbers. Match List-I with List-II and select the correct answer using the codes given below the lists:  


Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 16

Ans. (d) Euler number is concerned with pressure force and this choice is available for A in code (d) only. If one is confident, then there is no need to look for items B, C and D. However a cross checks will show that Froude number is concerned with gravity force, Mach number with elastic force, and Weber number with surface tension. Hence the answer is (d) only.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 17

Kinematic similarity between model and prototype is the similarity of 

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 17

Ans. (c) Kinematic similarity between a model and its prototype is said to exist if
the flow patterns are in geometric i.e. velocity, acceleration etc are similar.
Remember discharge is not related with kinematic similarity.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 18

A model test is to be conducted in a water tunnel using a 1: 20 model of a submarine, which is to travel at a speed of 12 km/h deep under seasurface. The water temperature in the tunnel is maintained, so that is kinematic viscosity is half that of sea water. At what speed is the model test to be conducted to produce useful data for the prototype? 

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 18

Ans. (d) Apply Reynolds Model law.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 19

A ship model 1/60 scale with negligible friction is tested in a towing tank at a speed of 0.6 m/s. If a force of 0.5 kg is required to tow themodel, the propulsive force required to tow the prototype ship will be: 

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 19

Ans. (c)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 20

Assertion (A): Reynolds number must be same for the model andprototype immersed in subsonic flows.  
Reason (R): Equality of Reynolds number for the model and prototypesatisfies the dynamic similarity criteria.

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 20

Ans. (b)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 21

A sphere is moving in water with a velocity of 1.6 m/s. Another sphere of twice the diameter is placed in a wind tunnel and tested with airwhich is 750 times less dense and 60 times less viscous than water. The velocity of air that will give dynamically similar conditions is: 

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 21

Ans. (b)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 22

A1:256 scale model of a reservoir is drained in 4 minutes by opening the sluice gate. The time required to empty the prototype will be: 

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 22

Ans. (b)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 23

A 1:20 model of a spillway dissipates 0.25 hp. The corresponding prototype horse power dissipated will be:  

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 23

Ans. (d) Pr = Lr3.5 = 203.5 Therefore Pp = 0.25 × 203.5 = 8944 hp

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 24

A model test is to be conducted for an under water structure which each likely to be exposed for an under water structure, which is likelyto be exposed to strong water currents. The significant forces areknown to the dependent on structure geometry, fluid velocity, fluiddensity and viscosity, fluid depth and acceleration due to gravity.Choose from the codes given below, which of the following numbers must match for the model with that of the prototype:  
1. Mach number
2. Weber number
3. Froude number
4. Reynolds number.

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 24

Ans. (d)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 25

The square root of the ratio of inertia force to gravity force is called 

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 25

Ans. (b)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 26

Consider the following statements:  
1. Complete similarity between model and prototype envisages geometric and dynamic similarities only.
2. Distorted models are necessary where geometric similarity is notpossible due to practical reasons.
3. In testing of model of a ship, the surface tension forces are generallyneglected.
4. The scale effect takes care of the effect of dissimilarity between model and prototype.
Which of these statements are correct?

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 26

Ans. (c) 1 is wrong. Complete similarity between model and prototype envisages
geometric, kinematic and dynamic similarities only. 4 is also wrong. The scale effect takes care of the effect of dissimilarity (size difference) between model and prototype.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 27

Why is multi-staging in centrifugal pumps used?  

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 27

Ans. (b) Centrifugal pumps are able to develop low pressure multi-staging in
centrifugal pumps is done for high head.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 28

Which one of the following statements is relevant to the specific speedof a centrifugal pump?  

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 28

Ans. (a)

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 29

Consider the following statements regarding the specific speed of acentrifugal pump:  
1. Specific speed is defined as the speed of a geometrically similar pump developing unit power under unit head.
2. At the same specific speed, the efficiency is greater with largercapacity.
3. The specific speed increases with the increase in outer blade angle.
4. The specific speed varies directly as the square root of the pump discharge.
Of these statements:

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 29

Ans. (b) Specific speed is defined as the speed of a geometrically similar turbine
developing unit power under unit head. BUT specific speed of a pump is defined
as the speed of a geometrically similar pump of such a size that under corresponding  conditions it would deliver unit volume flow of liquid against unit
head. That so why statement 1 is wrong.

Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 30

Assertion (A): With increase in discharge in a single stage centrifugal pump the BHP goes on increasing but beyond a certain discharge the BHP starts decreasing.  
Reason (R): Efficiency of the pump starts decreasing beyond a certain discharge.

Detailed Solution for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 - Question 30

Ans. (d) A is false and R is true.

29 docs|220 tests
Information about Test: Dimensional & Model Analysis, Centrifugal Pump - 2 Page
In this test you can find the Exam questions for Test: Dimensional & Model Analysis, Centrifugal Pump - 2 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Dimensional & Model Analysis, Centrifugal Pump - 2, EduRev gives you an ample number of Online tests for practice

Top Courses for Mechanical Engineering

Download as PDF

Top Courses for Mechanical Engineering