 MEASUREMENTS & INSTRUMENTATION
1. MEASURING INSTRUMENT
CHARACTERISTICS
Generalized Measuring Instrument: The block diagram of generalized measuring
system may be represented as:
IMPORTANT DEFINITIONS:
Accuracy: Closeness with which an instrument reading approaches the true value
of the variable being measured. It can be improved by recalibration.
Precision: It is a measure of the degree to which successive measurement differ
from one another.
? It is design time characteristic.
High precision does not mean high accuracy. A highly precise instrument may be
inaccurate.
Ex: If reading are 101, 102, 103, 104, 105. Most precise value is 103
Resolution: The smallest change in measured value to which the instrument will
respond. It is improved by re-calibrating the instrument.
Sensitivity: It is ratio of change in output per unit change in input quantity of the
instrument. It is design time characteristic.
Drift: It means deviation in output of the instrument from a derived value for a
particular input.
Reproducibility: It is degree of closeness with which a given value may be
measured repeatedly for a given period of time.
Repeatability: It is degree of closeness with which a given input is repeatably
indicated for a given set of recordings.
Errors:
1. Absolute Error/Static Error/Limiting Error:
T
A A A
m
? ? ? A
m
? Measured value of quantity of actual value
T
A ? True value of quantity or nominal value
2. Relative Error:
T
T T
A A A
A A
m
r
? ? ? ? ? ? 3. Percent Error:
T
A
% 100
A
r
? ? ? ? Instrument Error is generally given in percent error.
4. Percentage Error at reading ‘x’:
,
Full Scale Reading
% [% , Full scale]
r x r
x
? ? ? ? ? ? ? ? ? ?
Page 2


 MEASUREMENTS & INSTRUMENTATION
1. MEASURING INSTRUMENT
CHARACTERISTICS
Generalized Measuring Instrument: The block diagram of generalized measuring
system may be represented as:
IMPORTANT DEFINITIONS:
Accuracy: Closeness with which an instrument reading approaches the true value
of the variable being measured. It can be improved by recalibration.
Precision: It is a measure of the degree to which successive measurement differ
from one another.
? It is design time characteristic.
High precision does not mean high accuracy. A highly precise instrument may be
inaccurate.
Ex: If reading are 101, 102, 103, 104, 105. Most precise value is 103
Resolution: The smallest change in measured value to which the instrument will
respond. It is improved by re-calibrating the instrument.
Sensitivity: It is ratio of change in output per unit change in input quantity of the
instrument. It is design time characteristic.
Drift: It means deviation in output of the instrument from a derived value for a
particular input.
Reproducibility: It is degree of closeness with which a given value may be
measured repeatedly for a given period of time.
Repeatability: It is degree of closeness with which a given input is repeatably
indicated for a given set of recordings.
Errors:
1. Absolute Error/Static Error/Limiting Error:
T
A A A
m
? ? ? A
m
? Measured value of quantity of actual value
T
A ? True value of quantity or nominal value
2. Relative Error:
T
T T
A A A
A A
m
r
? ? ? ? ? ? 3. Percent Error:
T
A
% 100
A
r
? ? ? ? Instrument Error is generally given in percent error.
4. Percentage Error at reading ‘x’:
,
Full Scale Reading
% [% , Full scale]
r x r
x
? ? ? ? ? ? ? ? ? ? MEASUREMENTS & INSTRUMENTATION
Error due to combination of quantities:
1. Error due to Sum/Difference of quantities
1 2
X x x ? ? 1 1 2 2
1 2
X
%
X X X
r
x x x x
x x
? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 2. Error due to product or quotient of quantities
1 2 3
X x x x ? Or
1
2 3
x
x x
or
1 2 3
1
x x x
3 1 2
1 2 3
X
X
x x x
x x x
? ? ? ? ? ? ? ? ? ? ? ? ? ? 3. Composite factors
1 2
1 2
1 2
X
X x .
X
n m
x x
x n m
x x
? ? ? ? ? ? ? ? ? ? ? ? ? CLASSIFICATION OF ERRORS:
Standards of EMF:
(a) Saturated Weston cell is used for Primary standard of emf.
Its emf is 1.01864 volt, maximum current drawn is 100 A. ? It contains
4
CdSO crystal and its internal resistance is 600 to 800 . ? ? (b) Unsaturated Weston cell is used for secondary standards. Its emf is 1.0180
to 1.0194 volt and does not have
4
CdSO crystal.
Standard of Resistance:
Maganin (Ni + Cu + Mn)
Nickel 4%
Magnese12% [High Resistivity and low temperature coefficient]
Copper 84%
Inductive effect of resistance can be eliminated, using Bifilar winding.
Standard of Time and Frequency:
Atomic clock is used as primary standard of time and frequency. Quartz, Rubidium
crystal is used as secondary standard of time and frequency. Example: Cesium 133,
hydrogen maser etc.
Page 3


 MEASUREMENTS & INSTRUMENTATION
1. MEASURING INSTRUMENT
CHARACTERISTICS
Generalized Measuring Instrument: The block diagram of generalized measuring
system may be represented as:
IMPORTANT DEFINITIONS:
Accuracy: Closeness with which an instrument reading approaches the true value
of the variable being measured. It can be improved by recalibration.
Precision: It is a measure of the degree to which successive measurement differ
from one another.
? It is design time characteristic.
High precision does not mean high accuracy. A highly precise instrument may be
inaccurate.
Ex: If reading are 101, 102, 103, 104, 105. Most precise value is 103
Resolution: The smallest change in measured value to which the instrument will
respond. It is improved by re-calibrating the instrument.
Sensitivity: It is ratio of change in output per unit change in input quantity of the
instrument. It is design time characteristic.
Drift: It means deviation in output of the instrument from a derived value for a
particular input.
Reproducibility: It is degree of closeness with which a given value may be
measured repeatedly for a given period of time.
Repeatability: It is degree of closeness with which a given input is repeatably
indicated for a given set of recordings.
Errors:
1. Absolute Error/Static Error/Limiting Error:
T
A A A
m
? ? ? A
m
? Measured value of quantity of actual value
T
A ? True value of quantity or nominal value
2. Relative Error:
T
T T
A A A
A A
m
r
? ? ? ? ? ? 3. Percent Error:
T
A
% 100
A
r
? ? ? ? Instrument Error is generally given in percent error.
4. Percentage Error at reading ‘x’:
,
Full Scale Reading
% [% , Full scale]
r x r
x
? ? ? ? ? ? ? ? ? ? MEASUREMENTS & INSTRUMENTATION
Error due to combination of quantities:
1. Error due to Sum/Difference of quantities
1 2
X x x ? ? 1 1 2 2
1 2
X
%
X X X
r
x x x x
x x
? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 2. Error due to product or quotient of quantities
1 2 3
X x x x ? Or
1
2 3
x
x x
or
1 2 3
1
x x x
3 1 2
1 2 3
X
X
x x x
x x x
? ? ? ? ? ? ? ? ? ? ? ? ? ? 3. Composite factors
1 2
1 2
1 2
X
X x .
X
n m
x x
x n m
x x
? ? ? ? ? ? ? ? ? ? ? ? ? CLASSIFICATION OF ERRORS:
Standards of EMF:
(a) Saturated Weston cell is used for Primary standard of emf.
Its emf is 1.01864 volt, maximum current drawn is 100 A. ? It contains
4
CdSO crystal and its internal resistance is 600 to 800 . ? ? (b) Unsaturated Weston cell is used for secondary standards. Its emf is 1.0180
to 1.0194 volt and does not have
4
CdSO crystal.
Standard of Resistance:
Maganin (Ni + Cu + Mn)
Nickel 4%
Magnese12% [High Resistivity and low temperature coefficient]
Copper 84%
Inductive effect of resistance can be eliminated, using Bifilar winding.
Standard of Time and Frequency:
Atomic clock is used as primary standard of time and frequency. Quartz, Rubidium
crystal is used as secondary standard of time and frequency. Example: Cesium 133,
hydrogen maser etc.
MEASUREMENTS & INSTRUMENTATION
2. CLASSIFICATION OF ELECTRICAL
INSTRUMENTS
Absolute Instrument: It gives the value of parameters under measurement in terms
of the physical constant of the instrument.
e.g.? Transient Galvanometer, Rayleigh current balance etc.
Secondary Instrument:
It gives the value of parameter for directly under measurement.
e.g.? voltmeter, thermometer, pressure gauge etc.
Note: Absolute instruments are highly accurate than secondary instrument as they
contain less number of moving mechanical parts resulting in a lower operational of
power consumption.
Classification of analog instruments
1. Indicating type:  Voltmeter, Ammeter, Wattmeter .
2. Recording type: Recorders.
3. Integrating type: Energy meter.
4. Comparison type: Potentiometer and bridges or null deflection.
5. Deflecting type: PMMC
Note: Null deflecting instruments are highly accurate as compression to deflecting
instrument as their operational power consumption at zero deflection is zero.
Principle of Operation of Analog Instruments:
Magnetic effect: Moving Iron, PMMC, Dynamometer
Induction effect: Energy meter
Heating effect: Thermocouple and Hotwire type, Bolometer
Electro static effect: Electro static type voltmeter
Hall Effect: Poynting vector type voltmeter, Flux-meter
Damping system used in indicating instruments:
It is provided in the instrument which helps the moving system of the instrument to
reach to final position at earliest.
Page 4


 MEASUREMENTS & INSTRUMENTATION
1. MEASURING INSTRUMENT
CHARACTERISTICS
Generalized Measuring Instrument: The block diagram of generalized measuring
system may be represented as:
IMPORTANT DEFINITIONS:
Accuracy: Closeness with which an instrument reading approaches the true value
of the variable being measured. It can be improved by recalibration.
Precision: It is a measure of the degree to which successive measurement differ
from one another.
? It is design time characteristic.
High precision does not mean high accuracy. A highly precise instrument may be
inaccurate.
Ex: If reading are 101, 102, 103, 104, 105. Most precise value is 103
Resolution: The smallest change in measured value to which the instrument will
respond. It is improved by re-calibrating the instrument.
Sensitivity: It is ratio of change in output per unit change in input quantity of the
instrument. It is design time characteristic.
Drift: It means deviation in output of the instrument from a derived value for a
particular input.
Reproducibility: It is degree of closeness with which a given value may be
measured repeatedly for a given period of time.
Repeatability: It is degree of closeness with which a given input is repeatably
indicated for a given set of recordings.
Errors:
1. Absolute Error/Static Error/Limiting Error:
T
A A A
m
? ? ? A
m
? Measured value of quantity of actual value
T
A ? True value of quantity or nominal value
2. Relative Error:
T
T T
A A A
A A
m
r
? ? ? ? ? ? 3. Percent Error:
T
A
% 100
A
r
? ? ? ? Instrument Error is generally given in percent error.
4. Percentage Error at reading ‘x’:
,
Full Scale Reading
% [% , Full scale]
r x r
x
? ? ? ? ? ? ? ? ? ? MEASUREMENTS & INSTRUMENTATION
Error due to combination of quantities:
1. Error due to Sum/Difference of quantities
1 2
X x x ? ? 1 1 2 2
1 2
X
%
X X X
r
x x x x
x x
? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 2. Error due to product or quotient of quantities
1 2 3
X x x x ? Or
1
2 3
x
x x
or
1 2 3
1
x x x
3 1 2
1 2 3
X
X
x x x
x x x
? ? ? ? ? ? ? ? ? ? ? ? ? ? 3. Composite factors
1 2
1 2
1 2
X
X x .
X
n m
x x
x n m
x x
? ? ? ? ? ? ? ? ? ? ? ? ? CLASSIFICATION OF ERRORS:
Standards of EMF:
(a) Saturated Weston cell is used for Primary standard of emf.
Its emf is 1.01864 volt, maximum current drawn is 100 A. ? It contains
4
CdSO crystal and its internal resistance is 600 to 800 . ? ? (b) Unsaturated Weston cell is used for secondary standards. Its emf is 1.0180
to 1.0194 volt and does not have
4
CdSO crystal.
Standard of Resistance:
Maganin (Ni + Cu + Mn)
Nickel 4%
Magnese12% [High Resistivity and low temperature coefficient]
Copper 84%
Inductive effect of resistance can be eliminated, using Bifilar winding.
Standard of Time and Frequency:
Atomic clock is used as primary standard of time and frequency. Quartz, Rubidium
crystal is used as secondary standard of time and frequency. Example: Cesium 133,
hydrogen maser etc.
MEASUREMENTS & INSTRUMENTATION
2. CLASSIFICATION OF ELECTRICAL
INSTRUMENTS
Absolute Instrument: It gives the value of parameters under measurement in terms
of the physical constant of the instrument.
e.g.? Transient Galvanometer, Rayleigh current balance etc.
Secondary Instrument:
It gives the value of parameter for directly under measurement.
e.g.? voltmeter, thermometer, pressure gauge etc.
Note: Absolute instruments are highly accurate than secondary instrument as they
contain less number of moving mechanical parts resulting in a lower operational of
power consumption.
Classification of analog instruments
1. Indicating type:  Voltmeter, Ammeter, Wattmeter .
2. Recording type: Recorders.
3. Integrating type: Energy meter.
4. Comparison type: Potentiometer and bridges or null deflection.
5. Deflecting type: PMMC
Note: Null deflecting instruments are highly accurate as compression to deflecting
instrument as their operational power consumption at zero deflection is zero.
Principle of Operation of Analog Instruments:
Magnetic effect: Moving Iron, PMMC, Dynamometer
Induction effect: Energy meter
Heating effect: Thermocouple and Hotwire type, Bolometer
Electro static effect: Electro static type voltmeter
Hall Effect: Poynting vector type voltmeter, Flux-meter
Damping system used in indicating instruments:
It is provided in the instrument which helps the moving system of the instrument to
reach to final position at earliest.
 MEASUREMENTS & INSTRUMENTATION
Electromagnetic damping: Galvanometer and moving coil type
Eddy current damping: PMMC voltmeter and energy meter
Air frictional damping: Moving iron and dynamometer
Fluid friction damping: Electrostatic type voltmeter
? PMMC Instruments are used only for DC measurements.
? Induction type instruments are used only for AC measurements.
? Hotwire and Thermal type instruments measure RMS value of input.
? Electrostatic type instruments are used to measure high voltages in kV.
? Rectifier type instruments responds to average value.
Permanent Magnet Moving Coil instruments:
? These are also called self shielding instruments.
? Aluminium former is used to provide eddy current damping.
? Magnetic field in these is in range of 0.1 to
2
1wb/ m which is strong field.
? Control spring which is made of phosphor-bronze material in these instruments
provides a control force and also provides a path for current entering to moving
coil.
? If control spring is broken, current through the coil is zero and instrument reads
zero.
? It is used for measurement of DC only.
? Material used for magnet in PMMC is Alnico and Alcomax (Al + Co +Ni).
? Torque to weight ratio of the moving system should be high and equal to 0.1,
0.1 ; It decides sensitivity which is high in PMMC
T
weight
? ? It can sense a current upto 50 ? A.
? Deflecting torque (T
d
) = NBAI
? Controlling torque (T
c
) = k? At balance T
d
= T
c
G NBA
I I
K K
? ? ? N ? Number of turns A ? Area of cross section of vowing coil
B ? Magnetic flux I ? Current through coil
Key points:
The control spring in PMMC have dual utility, they not only produce controlling
torque but also used to lead the current into the system.
Source of Errors:
? Ageing effect of the permanent magnet (can be reduced by using a pre-edged
magnet)
? Temperature effect of coil and the control spring.
Read More
27 videos|328 docs

Top Courses for Electrical Engineering (EE)

Explore Courses for Electrical Engineering (EE) exam

Top Courses for Electrical Engineering (EE)

Signup for Free!
Signup to see your scores go up within 7 days! Learn & Practice with 1000+ FREE Notes, Videos & Tests.
10M+ students study on EduRev
Related Searches

Summary

,

Free

,

Viva Questions

,

Extra Questions

,

Exam

,

Electrical & Electronic Measurements Formulas for GATE EE Exam | GATE Notes & Videos for Electrical Engineering - Electrical Engineering (EE)

,

MCQs

,

shortcuts and tricks

,

Previous Year Questions with Solutions

,

past year papers

,

Electrical & Electronic Measurements Formulas for GATE EE Exam | GATE Notes & Videos for Electrical Engineering - Electrical Engineering (EE)

,

mock tests for examination

,

Semester Notes

,

Sample Paper

,

Objective type Questions

,

study material

,

pdf

,

Important questions

,

ppt

,

Electrical & Electronic Measurements Formulas for GATE EE Exam | GATE Notes & Videos for Electrical Engineering - Electrical Engineering (EE)

,

practice quizzes

,

video lectures

;