Pre-treatment & Physical treatment: Coagulation and flocculation – Part 1 

GENERAL

Coagulation has been defined as the addition of a positively charged ion such as Al3+, Fe3+ or catalytic polyelectrolyte that results in particle destabilization and charge neutralization. 

  • The purpose of coagulation is removal of finely divided suspended solids and colloidal material from the waste liquid. 
  • These contaminants cannot be separated by sedimentation alone except by the use of reasonably long detention periods; truly colloidal particles cannot be removed by settling. 
  • If these suspended pollutants are organic, they can often be oxidized by biological means, as on trickling filter; biochemical oxidation, however, is slower for suspended matter than for dissolved organic contaminants. If the quantity of insoluble organic matter is large, bio-oxidation equipment must be increased in size to care for this added duty; it is usually more economical to remove the greater part of such matter by chemical coagulation instead of in a trickling filter or activated sludge tank. 

 

Flocculation and Settling  

Flocculation is the formation of clumps or flocs of suspended solids by agglomeration of smaller suspended particles.  

  • Most chemical precipitates do not possess the property of flocculation to any appreciable degree, but rather tend to form dense, compact, crystalline particles that settle rapidly.  
  • Precipitates of ferric hydroxide, aluminum hydroxide, silica, and certain other substances formed by chemical reaction of coagulant chemicals, however, have the property of forming large flocs of high surface area. As these flocs move through the liquid in a settling tank, they remove other suspended solids by adsorption or mechanical sweeping, and hence perform a better clarification than could be achieved by plain sedimentation alone. 
  • Flocculation is aided by mild agitation for a period of 20 to 60 minutes, to allow time for maximum floc formation and growth.  
  • The agitation should be gentle, in order not to break flocs already formed. Gentle air agitation has also been employed to promote floc growth.  
  • After the floc has formed and grown to its most effective size, the waste passes to a sedimentation chamber for solids removal. Floc formation and growth may be retarded or stopped by surface-active chemicals such as soaps and synthetic detergents. 


COAGULATION FUNDAMENTALS  

Colloidal solutions that do not agglomerate naturally are called stable. This is due their large surface-to-volume ratio resulting from their very small size. In these small particles, molecular arrangements within crystals, loss of atoms due to abrasion of the surfaces, or other factors causes their surfaces to be charged.
 The colloids contained in the water are negatively charged at pH>pHiso and positively at pH<pHiso. These colloids are stable due to the repulsive forces between the negative charges. These colloids are destabilized by positively charged ions formed from the hydrolysis of coagulants. Destabilization of colloidal particles can be influenced by the  double layer compression, adsorption and charge neutralization, entrapment in precipitates (sweep flocculation) and interparticle bridging. 

1. Double layer compression: The negative colloid and its positively charged atmosphere produce an electrical potential across the diffuse layer. This is highest at the surface and drops off progressively with distance, approaching zero at the outside of the diffuse layer and is known as Zeta potential.  

  • When a coagulant is added, it destabilizes the negatively charged particles. A cationic coagulant such as a metal salt reduces the zeta potential of the particles by adding positive charge. 
  • Double layer compression involves adding salts to the system. As the ionic concentration increases, the double layer and the repulsion energy curves are compressed until there is no longer an energy barrier. Particle agglomeration occurs rapidly under these conditions .  
  • The thickness of the double layer depends upon the concentration of ions in solution. A higher level of ions means more positive ions are available to neutralize the colloid. The result is a thinner double layer. 

2. Adsorption and charge neutralization: Inorganic coagulants (such as alum, Ferrous sulphate) often work through charge neutralization. When these metal based coagulants are added to water, it dissociates and metal ions formed. Fe2+/Al3+ are liberated, if ferrous salt/alum is used. Liberated Fe2+/Al3+ and OH ions react to form various monomeric and polymeric hydrolyzed species.  The concentration of the hydrolyzed metal species depends on the metal concentration, and the solution pH. The percentage of Fe2+ and Al3+ hydrolytic products can be calculated from the following stability constants : 

Pre Treatment & Physical Treatment: Coagulation & Flocculation - 1 | Environmental Engineering - Civil Engineering (CE)
Pre Treatment & Physical Treatment: Coagulation & Flocculation - 1 | Environmental Engineering - Civil Engineering (CE)

 The speciation diagram of Fe2+ and Al3+ as drawn using above stability constants is presented in Figure 3.5.1 and Figure 3.5.2, respectively. 

Pre Treatment & Physical Treatment: Coagulation & Flocculation - 1 | Environmental Engineering - Civil Engineering (CE)            Pre Treatment & Physical Treatment: Coagulation & Flocculation - 1 | Environmental Engineering - Civil Engineering (CE)

Figure 3.5.1. Speciation diagram of Fe2+                                                  Figure 3.5.2. Speciation diagram of Al3+

 

It can be seen from speciation diagram of Fe(II) ions that the dominant soluble species are Fe2+ and Fe(OH)3- at low and high pH, respectively. The hydrolysis constants for aluminum cover a very narrower range, and all of the aluminum deprotonations are ‘squeezed’ into an interval of less than 2 unit. Therefore, apart from a narrow pH region approximately 5.5–6.5, the dominant soluble species are Al3+ and Al(OH)4- at low and high pH, respectively. 

Adsorption of the metal hydrolysed products on the colloid surface causes charge neutralization, which brings about van der Walls forces become dominant. Charge neutralization alone will not necessarily produce macro-flocs (flocs that can be seen with the naked eye). Micro-flocs (which are too small to be seen) may form but will not aggregate quickly into visible flocs. The polymeric hydrolyzed species possess high positive charges, and adsorbed to the surface of the negative colloids. This results in a reduction of the zeta potential to a level where the colloids are destabilized. The destabilized particles, along with their adsorbed hydro-metallic hydroxometallic complexes, aggregate by interparticulate Van der Waals forces. These forces are aided by the gentle mixing in water . When a coagulant forms threads or fibers which attach to several colloids, capturing and binding them together, this phenomenon is known as bridging. Some synthetic polymers and organic polyelectrolytes, instead of metallic salts, are used to assist interparticle bridging. 

Adsorption sites on the colloidal particles can adsorb a polymer molecule. A bridge is formed when one or more particles become adsorbed along the length of the polymer. Bridge particles intertwined with other bridged particles during the process. 

3. Sweep coagulation: Addition of relatively large doses of coagulants, usually aluminum or iron salts, which results in precipitation as hydrous metal oxides. Most of the colloids and some of dissolved solids are literally swept from the bulk of the water by becoming enmeshed in the settling hydrous oxide floc. This mechanism is often called sweep flocculation. Sweep floc is achieved by adding so much coagulant to the water that the water becomes saturated and the coagulant precipitates out. Then the particles get trapped in the precipitant as it settles down .

The document Pre Treatment & Physical Treatment: Coagulation & Flocculation - 1 | Environmental Engineering - Civil Engineering (CE) is a part of the Civil Engineering (CE) Course Environmental Engineering.
All you need of Civil Engineering (CE) at this link: Civil Engineering (CE)
14 videos|99 docs|98 tests

Top Courses for Civil Engineering (CE)

FAQs on Pre Treatment & Physical Treatment: Coagulation & Flocculation - 1 - Environmental Engineering - Civil Engineering (CE)

1. What is coagulation and flocculation in water treatment?
Ans. Coagulation and flocculation are two essential processes in water treatment. Coagulation involves the addition of chemicals that neutralize the electrical charges of suspended particles, causing them to come together and form larger clumps called flocs. Flocculation then helps to agglomerate these flocs into even larger particles that can be easily removed from the water.
2. What are the main chemicals used in coagulation and flocculation?
Ans. The most commonly used chemicals in coagulation and flocculation are coagulants and flocculants. Coagulants, such as aluminum sulfate (alum) or ferric chloride, are added to the water to neutralize the charges on suspended particles. Flocculants, typically high molecular weight polymers, are then added to promote the formation of larger flocs.
3. What are the benefits of coagulation and flocculation in water treatment?
Ans. Coagulation and flocculation play a crucial role in water treatment by effectively removing suspended particles, colloids, and organic matter from the water. These processes improve water clarity, reduce turbidity, and enhance the efficiency of subsequent treatment steps like sedimentation and filtration. Additionally, coagulation can aid in the removal of certain dissolved substances, including phosphates and heavy metals.
4. Can coagulation and flocculation remove all contaminants from water?
Ans. While coagulation and flocculation are effective in removing suspended particles and some dissolved substances, they may not be sufficient to eliminate all types of contaminants from water. For example, these processes are not designed to remove dissolved salts, such as those found in seawater. To address specific contaminants, additional treatment steps like filtration, disinfection, or reverse osmosis may be required.
5. How is the effectiveness of coagulation and flocculation measured?
Ans. The effectiveness of coagulation and flocculation is commonly measured by monitoring the turbidity of the water before and after treatment. Turbidity refers to the cloudiness or haziness caused by suspended particles. A decrease in turbidity indicates successful removal of particles, indicating the efficiency of coagulation and flocculation. Other parameters, such as particle size distribution and chemical oxygen demand (COD), can also be monitored to assess the treatment's overall performance.
14 videos|99 docs|98 tests
Download as PDF
Explore Courses for Civil Engineering (CE) exam

Top Courses for Civil Engineering (CE)

Signup for Free!
Signup to see your scores go up within 7 days! Learn & Practice with 1000+ FREE Notes, Videos & Tests.
10M+ students study on EduRev
Related Searches

shortcuts and tricks

,

Viva Questions

,

study material

,

Extra Questions

,

Exam

,

video lectures

,

pdf

,

Semester Notes

,

practice quizzes

,

Pre Treatment & Physical Treatment: Coagulation & Flocculation - 1 | Environmental Engineering - Civil Engineering (CE)

,

Summary

,

ppt

,

Pre Treatment & Physical Treatment: Coagulation & Flocculation - 1 | Environmental Engineering - Civil Engineering (CE)

,

Pre Treatment & Physical Treatment: Coagulation & Flocculation - 1 | Environmental Engineering - Civil Engineering (CE)

,

Objective type Questions

,

past year papers

,

Free

,

Sample Paper

,

Previous Year Questions with Solutions

,

MCQs

,

mock tests for examination

,

Important questions

;