Electrical Engineering (EE) Exam  >  Electrical Engineering (EE) Notes  >  Signals and Systems  >  Sampling & Reconstruction of Band Limited Signals

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) PDF Download

Sampling and Reconstruction of Band-Limited Signals

Band-limited signals: A Band-limited signal is one whose Fourier Transform is non-zero on only a finite interval of the frequency axis.
Specifically, there exists a positive number B such that X(f) is non-zero only in Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) . B is also called the Bandwidth of the signal.
To start off, let us first make an observation about the class of Band-limited signals.


Lets consider a Band-limited signal x(t) having a Fourier Transform X(f). Let the interval for which X(f) is non-zero be -B f B .

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

The RHS of the above equation is differentiable with respect to t any number of times as the integral is performed on a bounded domain and the integrand is differentiable with respect to t. Further, in evaluating the derivative of the RHS, we can take  Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)  inside the integral.

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

In general,

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

This implies that band limited signals are infinitely differentiable, therefore, very smooth .
We now move on to see how a Band-limited signal can be reconstructed from its samples.

 

Reconstruction of Time-limited Signals 

Consider first a signal y(t) that is time-limited, i.e. it is non-zero only in [-T/2, T/2].
Its Fourier transform Y(f) is given by:

 

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

Where is the periodic extension of y(t) as shown

Now, Recall that the coefficients of the Fourier series for a periodic signal x(t) are given by :

 

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

Comparing (1) and (2), you will find

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

 

That is, the Fourier Transform of the periodic signal Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) is nothing but the samples of the original transform.

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

Therefore, given that; y(t) is time-limited in [-T/2, T/2] and periodic, the entire information about y(t) is contained in just equispaced samples of its Fourier transform! It is the dual of this result that is the basis of Sampling and Reconstruction of Bandlimited signals :-
Knowing the Fourier transform is limited to, say [-B, B], the entire information about the transform (and hence the signal) is contained in just uniform samples of the (time) signal !

 

Reconstruction of Band-limited signals

Let us now apply the dual reasoning of the previous discussion to Band-limited signals. x(t) is Band-limited, with its Fourier transform X(f) being non-zero only in [-B, B]. The dual reasoning of the discussion in previous slide will imply that we can reconstruct X(f) perfectly in [-B, B] by using only the samples x( n / 2B ). Let's see how.

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

This time,   Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) is the  -nthFourier series co-efficient of Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) , the periodic extension of X(f).

 

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

  Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)(Fourier series in f -- fundamental period is 2B and  Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) is the  Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)  Fourier series coefficient)'

 

What is the Fourier inverse of  Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

The Fourier inverse of  is  Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) . Therefore, the Fourier inverse Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)is

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

 

Thus we see that if we multiply the original Band-limited signal with a periodic train of impulses (period 1/2B, with impulse at the origin of strength 1/2B ) we obtain a signal whose Fourier transform is a periodic extension of the original spectrum. So how does one retrieve the original signal from ? We need a mechanism that will blank out the spectrum of Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)  in  Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) , i.e: multiply the spectrum with :

 

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

 

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

In other words, we need  Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) to feed  to an LSI system, the Fourier transform of whose impulse response is the above function (recall the convolution theorem), i.e: one whose impulse response is:

 

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

An LSI system with above type of impulse response is called an Ideal Low Pass Filter .

 

The Sampling Theorem

On the basis of our discussion so far, we may state formally the Sampling Theorem.


Shannon-Whiltaker-Nyquist Sampling Theorem: 

A band-limited signal with band-width B may be reconstructed perfectly from its samples, if the signal is sampled uniformly at a rate greater than 2B.

Is it essential for the sampling rate to be greater than 2B, or is it acceptable to have a sampling rate of exactly 2B?
What will happen if the value of X(f) at -B and B are not zero? Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) will have values at B and -B different from those of X(f) (due to the periodic expension). Thus the transform of the output of the ideal low pass filter will not match that of the original signal at -B and B.  While finite, point mismatches in the transform will not matter, problems arise if X(f) has impulses at B or -B. Then, the output of the ideal low pass filter will be different from the original signal.


For example, consider sin(t). It has a bandwidth Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE). Say we sample the signal at a rate Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) What happens to all our samples? The signal has value zero at all multiples of π! You can't possibly reconstruct the signal from these samples. What went wrong? Lets look at the Fourier Transform involved:

 

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

Note that the periodic extension (taking period to be  Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) ) of this signal is identically zero. Thus an ideal low pass filter cannot retrieve this spectrum from its periodic extension.
 

This is why the Sampling theorem says one must use a sampling rate greater than 2B, where B is the Bandwidth of the signal. Say we sample at a rate Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)What is the Fourier transform of   Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

 

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

Now, an appropriate Low-pass filter can give us back the original signal !

Conclusion:

In this lecture you have learnt:

  • Band-limited signals are infinitely differentiable and very smooth.
  • Given that 'x(t)' is Band-limited with its Fourier transform 'X(f)' being non-zero only in [-B,B] , we can say that

    Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) has a
    spectrum that is the periodic extension of 'X(f)' with period 2B

    By passing Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)  through an appropriate Ideal Low-pass filter one can obtain back 'x(t)'. 

Shannon-Whiltaker-Nyquist Sampling Theorem:

A band-limited signal with band-width 'B' may be reconstructed perfectly from its samples, if the signal is sampled at a rate greater than '2B'.

The document Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE) is a part of the Electrical Engineering (EE) Course Signals and Systems.
All you need of Electrical Engineering (EE) at this link: Electrical Engineering (EE)
41 videos|52 docs|33 tests

Top Courses for Electrical Engineering (EE)

FAQs on Sampling & Reconstruction of Band Limited Signals - Signals and Systems - Electrical Engineering (EE)

1. What is band-limited signal sampling?
Ans. Band-limited signal sampling refers to the process of converting a continuous-time signal into a discrete-time signal by taking samples at regular intervals. The sampling rate must be at least twice the highest frequency present in the signal, according to the Nyquist-Shannon sampling theorem.
2. Why is it important to sample band-limited signals?
Ans. Sampling band-limited signals is important because it allows us to store, transmit, and process signals in a digital format. By converting continuous signals into discrete samples, we can utilize various digital signal processing techniques, such as filtering, analysis, and manipulation.
3. What is the purpose of reconstruction in band-limited signal processing?
Ans. Reconstruction in band-limited signal processing aims to recover the original continuous-time signal from its discrete samples. This process is necessary to obtain an accurate representation of the original signal and to avoid distortion or loss of information that may occur during the sampling process.
4. What are the implications of violating the Nyquist-Shannon sampling theorem?
Ans. Violating the Nyquist-Shannon sampling theorem can lead to a phenomenon called aliasing. Aliasing occurs when high-frequency components of a signal are incorrectly represented as lower-frequency components in the sampled signal. This can result in distortion and loss of information, making the reconstructed signal significantly different from the original signal.
5. How can we avoid aliasing in band-limited signal sampling?
Ans. To avoid aliasing, it is crucial to ensure that the sampling rate is at least twice the highest frequency present in the signal, as stated by the Nyquist-Shannon sampling theorem. This ensures that there is no overlap between frequency components and allows for accurate reconstruction of the original signal. Additionally, applying appropriate anti-aliasing filters before sampling can help remove high-frequency components that may cause aliasing.
41 videos|52 docs|33 tests
Download as PDF
Explore Courses for Electrical Engineering (EE) exam

Top Courses for Electrical Engineering (EE)

Signup for Free!
Signup to see your scores go up within 7 days! Learn & Practice with 1000+ FREE Notes, Videos & Tests.
10M+ students study on EduRev
Related Searches

Previous Year Questions with Solutions

,

shortcuts and tricks

,

pdf

,

study material

,

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

,

mock tests for examination

,

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

,

ppt

,

Summary

,

Objective type Questions

,

Extra Questions

,

Free

,

Important questions

,

video lectures

,

practice quizzes

,

MCQs

,

Viva Questions

,

Sample Paper

,

past year papers

,

Semester Notes

,

Exam

,

Sampling & Reconstruction of Band Limited Signals | Signals and Systems - Electrical Engineering (EE)

;