Electrical Engineering (EE) Exam  >  Electrical Engineering (EE) Notes  >  Basic Electrical Technology  >  Equivalent Circuit & Power Flow Diagram of IM

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE) PDF Download

Instructional Objectives

  • determine the induced emfs, and the currents, per phase in the stator and rotor windings,
  • find the relation between the rotor input, rotor copper loss and rotor output, in terms of slip,
  • calculate the various losses – iron, copper and mechanical, in an IM, and
  • find where do the losses occur.

 Introduction 

In the previous, i.e. second, lesson of this module, the construction (the stator and two types of rotor − squirrel cage and wound (slip-ring) one), of the three-phase induction motor (IM), has been described. Then, the principle of operation, i.e. production of torque, with the stator supplied from balanced three-phase supply and the rotor winding terminals short-circuited, is discussed. In this lesson, the equivalent circuit per phase of IM will be derived first, to be followed by the presentation of power flow diagram, wherein the various losses, and also where do they occur, are described.

Keywords: The induced voltages (emfs) in stator winding and rotor bar/winding, the equivalent circuit per phase of IM, the fictitious resistance in the circuit, input power to stator and rotor, losses – iron loss, stator and rotor copper loss, mechanical losses, output power.

The induced emf per phase, in the motor windings 

The induced emf per phase in the stator winding is nearly equal to the input voltage per phase, and is given by

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

where,

Vs = Input voltage (V) per phase, to the stator winding

Es = Induced emf (V) per phase, in the stator winding  

φ = Flux (Wb) per pole

f = Frequency (Hz or c/s) of the input voltage

Zs = 2 ⋅ Ts = No. of stator conductors in series per phase

Ts = No. of stator turns or coils in series per phase

kws = k ds ⋅ k ps = Stator winding factor

kds = Distribution factor of stator winding

kps = Pitch factor of stator winding 

 The above formula, not derived here, is a standard one available in any textbook. It is similar to the formula for the induced emf in a transformer, derived in the earlier module. As the winding in this case is stationary, with the rotating magnetic field rotating at a  speed of  Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)(also termed as the synchronous speed), the frequency of the induced emf in the stator winding is same as that of input frequency ( f=(p/2).ns), where, 

ns = Speed of the rotating magnetic field (rev/sec)

p = No. of poles for which the stator winding of IM is designed

The induced emf per phase at standstill (ωr = 0.0 , or s = 1.0 ) in the rotor winding (assuming a wound or slip-ring one), is given by 

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

where,

Er = Induced emf (V) per phase, in the rotor winding at standstill ( s = 1.0 )

f r = s ⋅ f = f = Frequency (Hz) in the rotor winding at standstill ( s = 1.0 )

Z r = 2 ⋅ Tr = No. of rotor conductors in series per phase

Tr = No. of rotor turns or coils in series per phase

k wr = k dr ⋅ k pr = Rotor winding factor

 k dr = Distribution factor of rotor winding

 k pr = Pitch factor of rotor winding 

It may be noted for the wound rotor, the number of poles in the rotor winding must be the same as those in the stator winding, which has been explained in the previous lesson (#30). The squirrel cage rotor can be considered as equivalent to a wound one.   The frequency of the induced emf in the rotor winding with the rotor rotating at any speed, is proportional to the relative speed between the speed of the rotating magnetic field, and that of the rotor, and is given by 

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

where,

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

 The ratio of the induced emf’s per phase, in the stator and rotor windings, with the rotor at standstill, is given by, 

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

assuming that the winding factor in both windings are same. It may be noted that the induced voltage per phase in the winding is proportional to the effective turns per phase, of the winding (=kw.T ). The formula is similar to that obtained in a transformer, where the induced voltage per turn (Et =E/T) is the same in the two (primary/secondary) windings. 

 The induced emf in the rotor winding with the motor running at any speed is proportional to the rotor frequency ( f r = s ⋅ f ), and is given by

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

The currents in the balanced three-phase windings of the stator produce a resultant mmf, rotating at the synchronous speed (ns)  relative to stator conductors, which is stationary. Similarly, the currents in the balanced three-phase windings of the rotor (taken as a wound one) produce another resultant mmf, rotating at the speed of (n s − nr = s ⋅ ns) relative to rotor conductors in the same direction as that of the rotor, which rotates at a speed  ( nr =(1-s).ns) Hence, the speed of the resultant rotor mmf relative to stator conductors is (s.ns+nr=ns) The axes of the resultant rotor mmf rotate at the same speed as those of the resultant stator mmf, so that the mmfs are stationary relative to each other.

The equivalent circuit per phase, of the rotor 

The current per phase in the rotor winding (Fig. 31.1a) is given by 

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

where, 

r2 = Resistance ( Ω ) per phase, of the rotor winding 

x2= 2 ⋅π ⋅ f ⋅ l2= Leakage reactance ( Ω ) per phase, of the rotor winding at standstill ( s = 1.0 or  ωr = 0.0 ) 

The leakage reactance per phase of the rotor winding at any other speed  nis proportional to the rotor frequency  Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)and is given by x 2 s = s ⋅ x 2 .  The term in the denominator of the expression is the magnitude of the rotor impedance per phase at any other speed, which is Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE) with its phase angle as 

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)It may be noted that the subscript ‘2’ is used here, instead of ‘r’ earlier. Similarly, the subscript ‘1’ may be used, instead of ‘s’, i.e. stator. In the expression for the rotor current per phase, if both numerator and denominator is divided by the term s, I2 is 

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

The circuit of the rotor (Fig. 31.1a) can now be drawn as shown in Fig. 31.1b, from the equation given earlier. It may be noted here the input voltage per phase to the circuit is constant, i.e.  and the leakage reactance per phase is also constant,x2 both being same as at standstill, with the rotor frequency being same as line or input frequency. Also the phase angle of the impedance, whose magnitude is the term in the denominator, remains same as Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE) as obtained earlier. The circuit of Fig. 31.1b can be redrawn as shown in Fig. 31.1c, with the resistance  Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)now being shown as sum of two resistances, rotor resistance,r2and titious resistance, 

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE) The first part of the circuit consists of the rotor impedance at standstill, which is Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE) whose magnitude and phase angle are Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)and Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)respectively.  

The relation between rotor input, rotor copper loss and rotor output 

From the equivalent circuit (Fig. 31.1c) per phase of the rotor winding, the total input (W) to the rotor is Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)  Please note that the phase angle,Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)is the angle between the induced voltage and current (both in the rotor). The total input to the rotor is the power transferred from the stator via air gap.  The total copper loss in the rotor winding is Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE). The total output of the rotor is the total power loss in the fictitious resistance, r2 (1 − s) / s of the rotor circuit (Fig, 31.1c), and is given by  .Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE) The total rotor output is obtained also as the difference of the total rotor input and the total rotor copper loss. Alternatively, Total input to the rotor = Total rotor copper loss + Total rotor output It may be shown that

 Total rotor copper loss = s × Total rotor input,

or, Total rotor input = (1 / s) × Total rotor copper loss 

In terms of total rotor output, the relationships are as follows, 

Total rotor copper loss = [ s / (1 − s)] × Total rotor output, 

or, Total rotor output = {(1 − s ) / s] × Total rotor copper loss 

The relation between total rotor output and total rotor input is 

Total rotor output = (1 − s ) × Total rotor input 

or, Total rotor input = [1 /(1 − s )] × Total rotor output 

In the above discussion, total rotor output is the output in electrical terms, also termed as gross one, which includes mechanical, or friction and windage losses. The expression for gross power and torque developed, and the torque-speed or torque-slip characteristics of Induction motor along with other relevant points, will be presented in the next lesson. 

Power flow diagram 

 In the induction motor, efficiency is  

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE) as Input = output + losses 

The total losses are losses in both stator and rotor, and mechanical losses. The stator losses are iron or core loss and copper loss, i.e. loss in the stator winding resistance. The core loss is the sum of hysteresis and eddy current losses, with the frequency in the stator being line frequency of 50 Hz. Both the above losses are related to frequency. It may be noted here that the flux in the air gap is rated, as the input or supply voltage fed to the stator winding is rated with the frequency is also rated. The copper loss is proportional to the square of the current in the stator winding. The loss in the rotor is only copper loss as shown earlier, with the iron loss being low due to low frequency in the rotor core. For example, the rotor frequency ( f r = s f ) is only 2 Hz, if the slip is assumed as 4%, the speed being 1,440 rpm for a 4-pole motor. The line (input) frequency is 50 Hz. The iron loss is related to the frequency as stated earlier. The net output available at the shaft is the gross output minus the mechanical losses  Before coming to the power flow diagram in an Induction motor, total input power fed to the motor via stator (winding) is Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)where, V and I are the input voltage and current per phase, to the motor. 

Total input power to the motor (stator) = Stator losses (iron & copper) + Total input power to the rotor (or Power transferred via air gap)  Total input power to the rotor = Rotor copper loss + Total output power (gross)  Total output power (gross) = Mechanical losses + Total output power (net) [or Power available at the shaft] It may be noted that all the losses, excluding mechanical one, are total for all three phases, and as given earlier, iron losses in the rotor are very low..  

In this lesson – the third one of this module, the equivalent circuit per phase of an IM has been derived, starting with the formula for the induced emfs per phase, in both stator and rotor windings. The various losses and where do they occur, are described next, followed by presentation of power flow diagram for IM. In the next lesson as given earlier, the expression for gross power or torque developed, and the torque-speed or torque-slip characteristics of an IM, along with other relevant points, will be presented in detail.   

The document Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE) is a part of the Electrical Engineering (EE) Course Basic Electrical Technology.
All you need of Electrical Engineering (EE) at this link: Electrical Engineering (EE)
57 docs|62 tests

Top Courses for Electrical Engineering (EE)

57 docs|62 tests
Download as PDF
Explore Courses for Electrical Engineering (EE) exam

Top Courses for Electrical Engineering (EE)

Signup for Free!
Signup to see your scores go up within 7 days! Learn & Practice with 1000+ FREE Notes, Videos & Tests.
10M+ students study on EduRev
Related Searches

Previous Year Questions with Solutions

,

Extra Questions

,

Semester Notes

,

practice quizzes

,

study material

,

Objective type Questions

,

MCQs

,

ppt

,

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

,

Viva Questions

,

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

,

Free

,

mock tests for examination

,

Exam

,

pdf

,

past year papers

,

Important questions

,

Summary

,

Equivalent Circuit & Power Flow Diagram of IM | Basic Electrical Technology - Electrical Engineering (EE)

,

video lectures

,

shortcuts and tricks

,

Sample Paper

;