Electrical Engineering (EE) Exam  >  Electrical Engineering (EE) Tests  >  Test: Distribution Systems, Cables & Insulators of Power Systems - Electrical Engineering (EE) MCQ

Test: Distribution Systems, Cables & Insulators of Power Systems - Electrical Engineering (EE) MCQ


Test Description

10 Questions MCQ Test - Test: Distribution Systems, Cables & Insulators of Power Systems

Test: Distribution Systems, Cables & Insulators of Power Systems for Electrical Engineering (EE) 2024 is part of Electrical Engineering (EE) preparation. The Test: Distribution Systems, Cables & Insulators of Power Systems questions and answers have been prepared according to the Electrical Engineering (EE) exam syllabus.The Test: Distribution Systems, Cables & Insulators of Power Systems MCQs are made for Electrical Engineering (EE) 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Distribution Systems, Cables & Insulators of Power Systems below.
Solutions of Test: Distribution Systems, Cables & Insulators of Power Systems questions in English are available as part of our course for Electrical Engineering (EE) & Test: Distribution Systems, Cables & Insulators of Power Systems solutions in Hindi for Electrical Engineering (EE) course. Download more important topics, notes, lectures and mock test series for Electrical Engineering (EE) Exam by signing up for free. Attempt Test: Distribution Systems, Cables & Insulators of Power Systems | 10 questions in 30 minutes | Mock test for Electrical Engineering (EE) preparation | Free important questions MCQ to study for Electrical Engineering (EE) Exam | Download free PDF with solutions
Test: Distribution Systems, Cables & Insulators of Power Systems - Question 1

If r is the  radius of the conductor and R the radius of the sheath of the cable, the cable operates stably from the view point of dielectric strength if:

Detailed Solution for Test: Distribution Systems, Cables & Insulators of Power Systems - Question 1

The cable operates stably from the view point of dielectric strength if, 

Test: Distribution Systems, Cables & Insulators of Power Systems - Question 2

The insulation resistance of a cable of 10 km length is 1 MΩ. The resistance for a length of 40 km is

Detailed Solution for Test: Distribution Systems, Cables & Insulators of Power Systems - Question 2


l1 = 10 km, R1 = 1 MΩ, l2 = 40 km

1/R= 40/10

R2 = 1/4 = 0.25 MΩ

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Distribution Systems, Cables & Insulators of Power Systems - Question 3

Sheath losses can be eliminated by

Test: Distribution Systems, Cables & Insulators of Power Systems - Question 4

Armouring protect cables against

Test: Distribution Systems, Cables & Insulators of Power Systems - Question 5

Match List-l (Type of Cables) with List-ll (Operatng Voltages) and select the correct answer using the code given below the lists: 

Test: Distribution Systems, Cables & Insulators of Power Systems - Question 6

Consider the following statements:
1. AAC (All Aluminium conductors) are universaly employed for feeders as well as distributors.
2. The conductor size for a feeder is mainly governed by the permissible voltage drop in the line.
Which of the above statement(s) is/are true?

Detailed Solution for Test: Distribution Systems, Cables & Insulators of Power Systems - Question 6

ACSR conductors are universally employed for distribution systems (feeders as well as distributors), AAC can be used for distribution purpose provided the spans are small.
Hence, statement-1 is false.
The conductor size for a feeder is mainly governed by current carrying capacity and overall economy. Hence, 2 is also a false statement.

Test: Distribution Systems, Cables & Insulators of Power Systems - Question 7

Which of the following distribution systems is the most economical?

Test: Distribution Systems, Cables & Insulators of Power Systems - Question 8

For high voltage transmission lines, conductors are suspended from towers so as to

Test: Distribution Systems, Cables & Insulators of Power Systems - Question 9

The function of steel wire in an ACSR conductor is to

Test: Distribution Systems, Cables & Insulators of Power Systems - Question 10

The string efficiency of insulators can be increased by

Information about Test: Distribution Systems, Cables & Insulators of Power Systems Page
In this test you can find the Exam questions for Test: Distribution Systems, Cables & Insulators of Power Systems solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Distribution Systems, Cables & Insulators of Power Systems, EduRev gives you an ample number of Online tests for practice

Top Courses for Electrical Engineering (EE)

Download as PDF

Top Courses for Electrical Engineering (EE)