Chemical Engineering Exam  >  Chemical Engineering Tests  >  Heat Exchanger - 2 - Chemical Engineering MCQ

Heat Exchanger - 2 - Chemical Engineering MCQ


Test Description

10 Questions MCQ Test - Heat Exchanger - 2

Heat Exchanger - 2 for Chemical Engineering 2024 is part of Chemical Engineering preparation. The Heat Exchanger - 2 questions and answers have been prepared according to the Chemical Engineering exam syllabus.The Heat Exchanger - 2 MCQs are made for Chemical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Heat Exchanger - 2 below.
Solutions of Heat Exchanger - 2 questions in English are available as part of our course for Chemical Engineering & Heat Exchanger - 2 solutions in Hindi for Chemical Engineering course. Download more important topics, notes, lectures and mock test series for Chemical Engineering Exam by signing up for free. Attempt Heat Exchanger - 2 | 10 questions in 30 minutes | Mock test for Chemical Engineering preparation | Free important questions MCQ to study for Chemical Engineering Exam | Download free PDF with solutions
Heat Exchanger - 2 - Question 1

A heat exchanger with heat transfer surface area A and overall heat transfer coefficient U handles two fluids of heat capacities Cmax and Cmin. The parameter NTU (Number of transfer units) used in the analysis of heat exchanger is defined as

Heat Exchanger - 2 - Question 2

The equation of effectiveness ε = 1 - e-NTU for a heat exchanger is valid in the case of

1 Crore+ students have signed up on EduRev. Have you? Download the App
Heat Exchanger - 2 - Question 3

The overall heat transfer coefficient for a shell and tube heat exchanger for clean surfaces is Uo = 400 W/m2K. The fouling factor after one year of operation is found to be hdo = 2000 W/m2K. The overall heat transfer coefficient at this time is

Detailed Solution for Heat Exchanger - 2 - Question 3


Heat Exchanger - 2 - Question 4

A solar assisted air conditioning system, 1 kg/sec of ambient air is to be preheated by the same amount of air leaving the system. A counter-flow heat exchanger having an area of 60 m2 with overall heat transfer coefficient of 25 W/m2K is used for this purpose. Assuming cp for air is 1 kJ/kgK. The effectiveness of the heat exchanger is

Detailed Solution for Heat Exchanger - 2 - Question 4

Heat Exchanger - 2 - Question 5

Hot air enters a single pass counter flow heat exchanger at 700 K and leaves at 400 K the cooling water enters at 300 K and leaves at 600 K. The LMTD for the heat exchanger is

Detailed Solution for Heat Exchanger - 2 - Question 5

Heat Exchanger - 2 - Question 6

For the same inlet and outlet temperatures of hot and cold fluid, the LMTD is

Heat Exchanger - 2 - Question 7

Which one of the following graphs, showing temperature distributions of different heat exchangers, pertains steam condenser

Heat Exchanger - 2 - Question 8

In which type of heat exchanger is the inlet temperature difference between the hot and cold fluids is maximum

Detailed Solution for Heat Exchanger - 2 - Question 8

for parallel flow heat exchanger

Heat Exchanger - 2 - Question 9

In a counter flow heat exchanger, the product of specific heat and mass flow rate is same for the hot and cold fluids. If NTU is equal to 0.5 then the effectiveness of the heat exchanger is

Detailed Solution for Heat Exchanger - 2 - Question 9

Heat Exchanger - 2 - Question 10

When tc1 and tc2 are the temperatures of cold fluid at entry and exit respectively and th1 and th2 are the temperature of hot fluid at entry and exit point and cold fluid has lower heat capacity rate as compared to hot fluid then effectiveness of the heat exchanger is given by

Information about Heat Exchanger - 2 Page
In this test you can find the Exam questions for Heat Exchanger - 2 solved & explained in the simplest way possible. Besides giving Questions and answers for Heat Exchanger - 2, EduRev gives you an ample number of Online tests for practice
Download as PDF