Mechanical Engineering Exam  >  Mechanical Engineering Tests  >  Test: Welded & Riveted Joints - 3 - Mechanical Engineering MCQ

Test: Welded & Riveted Joints - 3 - Mechanical Engineering MCQ


Test Description

20 Questions MCQ Test - Test: Welded & Riveted Joints - 3

Test: Welded & Riveted Joints - 3 for Mechanical Engineering 2024 is part of Mechanical Engineering preparation. The Test: Welded & Riveted Joints - 3 questions and answers have been prepared according to the Mechanical Engineering exam syllabus.The Test: Welded & Riveted Joints - 3 MCQs are made for Mechanical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Welded & Riveted Joints - 3 below.
Solutions of Test: Welded & Riveted Joints - 3 questions in English are available as part of our course for Mechanical Engineering & Test: Welded & Riveted Joints - 3 solutions in Hindi for Mechanical Engineering course. Download more important topics, notes, lectures and mock test series for Mechanical Engineering Exam by signing up for free. Attempt Test: Welded & Riveted Joints - 3 | 20 questions in 60 minutes | Mock test for Mechanical Engineering preparation | Free important questions MCQ to study for Mechanical Engineering Exam | Download free PDF with solutions
Test: Welded & Riveted Joints - 3 - Question 1

Select the WRONG statement:

Test: Welded & Riveted Joints - 3 - Question 2

The strength of a riveted joint is equal to

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Welded & Riveted Joints - 3 - Question 3

According to IBR, the factor of safety of riveted joint should not be less than

Test: Welded & Riveted Joints - 3 - Question 4

Which one of the following is not an advantage of welded joints over riveted joint

Test: Welded & Riveted Joints - 3 - Question 5

The relationship between diameter of rivet hole and plate thickness (Unwin formula) is given by

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 5

The relation between diameter of rivet hole and plate thickness is given by unwin as
d = 6√t
where, d = diameter of rivet hole plate thickness

Test: Welded & Riveted Joints - 3 - Question 6

For longitudinal joint in boiler, the type of joint used is

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 6

The longitudinal joint in a boiler shell is usually Butt joint with two cover plates this joint is more efficient than lap joint. It is also stiffer and helps to maintain circularity of the shell.

Test: Welded & Riveted Joints - 3 - Question 7

The centre to centre distance between two consecutive rivets in a row is called

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 7

Test: Welded & Riveted Joints - 3 - Question 8

Strength of a rivet in bearing is given by
where
σb = bearing stress
σt = tensile stress
τ = shear stress

Test: Welded & Riveted Joints - 3 - Question 9

The objective of caulking in a riveted joint is to make the joint

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 9

Caulking is used to make the riveted joint leak proof or fluid tight in pressure vessel like steam boilers, air receivers and tank etc.

Test: Welded & Riveted Joints - 3 - Question 10

The important criterion in case of riveted joints for material storage and other ordinary tanks is

Test: Welded & Riveted Joints - 3 - Question 11

In a fillet welded joint, the weakest area of weld is

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 11

Because throat area is the minimum area and Athroat = h x L

Test: Welded & Riveted Joints - 3 - Question 12

A rivet in a structure shown in figure, has to support a load of 2 kN. If the primary and secondary shear stresses are 6.37 MPa and 13.50 MPa respectively, the maximum stress developed in the rivet is

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 12


Twisting moment = P x e
= 200 x 0.3 = 600 N-m 
From the figure
r1 = r2 = r3 = r4




Resultant



shear stress developed

Test: Welded & Riveted Joints - 3 - Question 13

A riveted joint (with four rivets numbered 1 to 4) as shown in the figure is subjected to an eccentric loading. The least and the most stressed rivets respectively are:

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 13

Since 2 is the nearest rivet to the line of action of the force hence, it will be most stressed rivet while 4 is very far from the line of action of the force hence it will be least stressed.

Test: Welded & Riveted Joints - 3 - Question 14

If the ratio of diameter of rivet hole to the pitch of rivets is 0.25 then tearing efficiency of the joint is

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 14


Test: Welded & Riveted Joints - 3 - Question 15

A bracket (shown in figure) is rigidly mounted on wall using four rivets. Each rivet is 6 mm in diameter and has an effective length of 12 mm. Direct shear stress (in MPa) in the most heavily loaded rivet is

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 15

There are four rivets, direct force on each rivet

Direct shear stress,

= 8.8 MPa

Test: Welded & Riveted Joints - 3 - Question 16

The diameter of a rivet will be if plate thickness is 8 mm

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 16

d = 6√t = 6√8 = 16.9mm 

Test: Welded & Riveted Joints - 3 - Question 17

A double riveted double cover butt joint in plates 20 mm thick is made with 25 mm diameter rivets at 100 mm pitch. The permissible stresses are σ= 120 MPa, τ = 100 MPa, σc= 150 MPa. Taking the strength of the rivet in double shear as twice that of single shear, the tearing resistance of the plate is

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 17

Test: Welded & Riveted Joints - 3 - Question 18

The permissible stress in a fillet weld is 100 N/mm2. The fillet weld has equal leg lengths of 15 mm each. The allowable shearing load on per cm length of the weld is

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 18

Shear stress is given by 


∴ Load/cm length is = 1060 N/mm
= 10.6 kN/cm

Test: Welded & Riveted Joints - 3 - Question 19

Two plates are joined together by means of single transverse and double parallel fillet welds as shown in the given figure. If the size of fillet is 5 mm and allowable shear load power mm is 300 N, what is the approximate length of each parallel fillet?

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 19

Total length of the weld = 2l+ 100
Allowable shear per mm is 300N
∴ 300 x (2l + 100) = 150 x 103
2l+ 100 = 500
l = 200 mm

Test: Welded & Riveted Joints - 3 - Question 20

A steel plate 100 mm wide and 10 mm thick welded to another steel plate by means of double parallel fillet welds

Q. The plates are subjected to a static tensile force of 50 kN. If the permissible shear stress in the weld is 94 N/mm2. Then required length of the welds is

Detailed Solution for Test: Welded & Riveted Joints - 3 - Question 20

Information about Test: Welded & Riveted Joints - 3 Page
In this test you can find the Exam questions for Test: Welded & Riveted Joints - 3 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Welded & Riveted Joints - 3, EduRev gives you an ample number of Online tests for practice

Top Courses for Mechanical Engineering

Download as PDF

Top Courses for Mechanical Engineering