Mechanical Engineering Exam  >  Mechanical Engineering Tests  >  Test: Vapour Compression Systems, Refrigerants - 2 - Mechanical Engineering MCQ

Test: Vapour Compression Systems, Refrigerants - 2 - Mechanical Engineering MCQ


Test Description

30 Questions MCQ Test - Test: Vapour Compression Systems, Refrigerants - 2

Test: Vapour Compression Systems, Refrigerants - 2 for Mechanical Engineering 2024 is part of Mechanical Engineering preparation. The Test: Vapour Compression Systems, Refrigerants - 2 questions and answers have been prepared according to the Mechanical Engineering exam syllabus.The Test: Vapour Compression Systems, Refrigerants - 2 MCQs are made for Mechanical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Vapour Compression Systems, Refrigerants - 2 below.
Solutions of Test: Vapour Compression Systems, Refrigerants - 2 questions in English are available as part of our course for Mechanical Engineering & Test: Vapour Compression Systems, Refrigerants - 2 solutions in Hindi for Mechanical Engineering course. Download more important topics, notes, lectures and mock test series for Mechanical Engineering Exam by signing up for free. Attempt Test: Vapour Compression Systems, Refrigerants - 2 | 30 questions in 90 minutes | Mock test for Mechanical Engineering preparation | Free important questions MCQ to study for Mechanical Engineering Exam | Download free PDF with solutions
Test: Vapour Compression Systems, Refrigerants - 2 - Question 1

The values of enthalpy at the beginning of compression, at the end of compression and at the end of condensation are 185 kJ/kg, 210 kJ/kg and 85 kJ/kg respectively. What is the value of the COP of the vapour compression refrigeration system?

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 1

Test: Vapour Compression Systems, Refrigerants - 2 - Question 2

Air cooling is used for freon compressors whereas water jacketing is adopted for cooling ammonia compressors. This is because

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Vapour Compression Systems, Refrigerants - 2 - Question 3

onsider the following statements in respect of absorption refrigeration and vapour compression refrigeration systems:

1. The former runs on low grade energy.

2. The pumping work in the former is negligible since specific volume of strong liquid solution is small.

3. The latter uses an absorber while former uses a generator.

4. The liquid pump alone replaces compressor of the latter.  

Which of these statements are correct? 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 4

For a heat pump working on vapour compression cycle, enthalpy values of the working fluid at the end of heat addition process, at the end of compression process, at the end of heat rejection process, and at the end of isenthalpic expansion process are 195 kJ/kg, 210 kJ/kg, and 90 kJ/kg respectively. The mass flow rate is 0.5 kg/s. Then the heating capacity of heat pump is, nearly

Test: Vapour Compression Systems, Refrigerants - 2 - Question 5

In a vapour compression plant, if certain temperature differences are to be maintained in the evaporator and condenser in order to obtain the necessary heat transfer, then the evaporator saturation temperature must be:

Test: Vapour Compression Systems, Refrigerants - 2 - Question 6

In milk chilling plants, the usual secondary refrigerant is:

Test: Vapour Compression Systems, Refrigerants - 2 - Question 7

A single-stage vapour compression refrigeration system cannot be used to produce ultralow temperatures because

Test: Vapour Compression Systems, Refrigerants - 2 - Question 8

The vapour compression refrigeration cycle is an inherently irreversible cycle, because

Test: Vapour Compression Systems, Refrigerants - 2 - Question 9

Consider the following statements pertaining to a vapour compression type refrigerator:

1.The condenser rejects heat to the surroundings from the refrigerant.  

2.The evaporator absorbs heat from the surroundings to be cooled.  

3.Both the condenser and evaporator are heat exchangers with refrigerant as a common medium.  

4.The amount of heat exchanged in condenser and evaporator are equal under steady conditions.  

Which of the above statements are correct? 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 10

The correct sequence of vapour compression (VC), vapour absorption (VA) and steam ejector (SE) refrigeration cycles in increasing order of the COP is:

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 10

The correct sequence of VC, VA and SE in increasing order of COP is VA, SE and VC, the Value being of the order of 0.3 to 0.4 0.5 to 0.8 and 4 to 5 respectively. 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 11

The leakage in a Freon-based refrigeration system can be detected by using a/an 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 12

Consider the following statements:

High condenser pressure in a refrigeration system can occur because 

1. The water flow rate is lower than the desired value.  

2. Non-condensable gases are present in the system  

3. Of accumulation of lubricating oil in condenser  

4. Of low charge of refrigerant in the system. 

Of these statements: 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 13

In system A vapour are superheated by 10°C in the evaporator while in system B vapour are superheated by 10°C in a liquid vapour regenerative heat exchanger, other conditions being the same. Then 

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 13

h1′ −h1= h3 − h3

Test: Vapour Compression Systems, Refrigerants - 2 - Question 14

Selection of a refrigerant for a vapour – compression system depends on which among the following?

Test: Vapour Compression Systems, Refrigerants - 2 - Question 15

Oil separator is NOT required in refrigeration system if:

Test: Vapour Compression Systems, Refrigerants - 2 - Question 16

Consider the following statements:

Moisture should be removed from refrigerants to avoid  

1. Compressor seal failure

2. Freezing at the expansion valve  

3. Restriction to refrigerant flow

4. Corrosion of steel parts  

Of these statements:  

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 16

All the statements about effect of moisture on refrigerant are correct. 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 17

ssertion (A): R-22 is used as a refrigerant in all refrigerators.  

Reason (R):  R-22 is non-toxic and non-inflammable. 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 18

Match List-I with List-II and select the correct answer using the codes given below the lists:

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 18

R (C − 1) ( H+1) F

Test: Vapour Compression Systems, Refrigerants - 2 - Question 19

Assertion (A): Freon-12 is odourless and its leakage cannot be easily detected. However, it is preferred in comfort air-conditioning.

Reason (R): It is almost impossible for Freon-12 leakage to attain a fatal concentration. 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 20

Match List-I with List-II and select the correct answer using the codes given below the lists:

Test: Vapour Compression Systems, Refrigerants - 2 - Question 21

The color of the flame of halide torch, in a case of leakage of Freon refrigerant, will change to:

Test: Vapour Compression Systems, Refrigerants - 2 - Question 22

What is an azeotrope? 

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 22

Azeotrope is a mixture of refrigerants without phase separation. 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 23

The leaks in a refrigeration system freon are detected by:

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 23

Several methods are available for the detection of leaks. The most common is the soap-bubble method. The other is the halide torch method used with fluorocarbons. 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 24

Match List-I (Chemical formula of refrigerant) with List-II (Numerical Designation) and select the correct answer using the codes given below the lists:

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 24

R(C – 1)(H + 1)F and Cl by balance and for inorganic refrigerant R(700 + Molecular weight). 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 25

Match List-I (Refrigerant) with List-II (Designation) and select the correct answer using the codes given below the lists:

Test: Vapour Compression Systems, Refrigerants - 2 - Question 26

Theoretical vapour compression refrigeration cycle is represented on a T-s diagram as

Test: Vapour Compression Systems, Refrigerants - 2 - Question 27

Match List-I (T-s diagram) with List-II (P-h diagrams) of vapour compression refrigeration cycles and select the correct answer using the codes given below the lists:

Test: Vapour Compression Systems, Refrigerants - 2 - Question 28

Replacing a water-cooled condenser with an air-cooled one in a vapour compression refrigeration system with constant evaporator pressure results in

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 28

Heat transfer co-efficient of gas very small compared to water hwater >> hair. So for same heat transfer temperature difference will be high

 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 29

The power required for the compressor in kw is 

Detailed Solution for Test: Vapour Compression Systems, Refrigerants - 2 - Question 29

Correct Answer :- c

Explanation : Since power is required for compressor in refrigeration is in compression cycle (1-2)

Hence, Power required = m (h2 -h1) = mo (h2 -hf)

Since for isentropic compression process.

s1 = s2 from figure. = 0.95

For entropy s = 0.95 the enthalpy h = 276.45 kJ /kg

h = h2 = 276.45 (From table)

Hence Power = 0.2(276.45 -237) 

= 7.9 kW

 

Test: Vapour Compression Systems, Refrigerants - 2 - Question 30

A good refrigerant should have

Information about Test: Vapour Compression Systems, Refrigerants - 2 Page
In this test you can find the Exam questions for Test: Vapour Compression Systems, Refrigerants - 2 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Vapour Compression Systems, Refrigerants - 2, EduRev gives you an ample number of Online tests for practice

Top Courses for Mechanical Engineering

Download as PDF

Top Courses for Mechanical Engineering