Mechanical Engineering Exam  >  Mechanical Engineering Tests  >  Test: Refrigerant Compressors - 1 - Mechanical Engineering MCQ

Test: Refrigerant Compressors - 1 - Mechanical Engineering MCQ


Test Description

20 Questions MCQ Test - Test: Refrigerant Compressors - 1

Test: Refrigerant Compressors - 1 for Mechanical Engineering 2024 is part of Mechanical Engineering preparation. The Test: Refrigerant Compressors - 1 questions and answers have been prepared according to the Mechanical Engineering exam syllabus.The Test: Refrigerant Compressors - 1 MCQs are made for Mechanical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Refrigerant Compressors - 1 below.
Solutions of Test: Refrigerant Compressors - 1 questions in English are available as part of our course for Mechanical Engineering & Test: Refrigerant Compressors - 1 solutions in Hindi for Mechanical Engineering course. Download more important topics, notes, lectures and mock test series for Mechanical Engineering Exam by signing up for free. Attempt Test: Refrigerant Compressors - 1 | 20 questions in 60 minutes | Mock test for Mechanical Engineering preparation | Free important questions MCQ to study for Mechanical Engineering Exam | Download free PDF with solutions
Test: Refrigerant Compressors - 1 - Question 1

A single-acting two-stage compressor with complete inter cooling delivers air at 16 bar. Assuming an intake state of 1 bar at 15°C, the pressure ratio per stage is:

Detailed Solution for Test: Refrigerant Compressors - 1 - Question 1

Pressure ratio of each stage must be same 

Test: Refrigerant Compressors - 1 - Question 2

A  refrigeration compressor designed to operate with R 22………. (can/cannot) be operated with R 12 because the condensing pressure of R22 at any give temperature is……..(higher/lower) than that of R 12.

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Refrigerant Compressors - 1 - Question 3

Which of the following statements does NOT apply to the volumetric efficiency of a reciprocating air compressor?

Test: Refrigerant Compressors - 1 - Question 4

Air     enters a compressor at a temperature of 27°C. The compressor pressure ratio is 4. Assuming an efficiency of 80%, the compressor work required in kJ/kg is:

Detailed Solution for Test: Refrigerant Compressors - 1 - Question 4

Test: Refrigerant Compressors - 1 - Question 5

Select statements from List-II matching the processes in List-I. Enter your answer as A, B if the correct choice for (1) is (A) and that for (2) is (B)

Test: Refrigerant Compressors - 1 - Question 6

A centrifugal compressor is suitable for which of the following? 

Test: Refrigerant Compressors - 1 - Question 7

Which type of valves is generally used in reciprocating refrigerant compressors?

Test: Refrigerant Compressors - 1 - Question 8

In a single stage reciprocating air compressor, the work done on air to compress it from suction pressure to delivery pressure will be minimum when the compression is 

Test: Refrigerant Compressors - 1 - Question 9

The capacity of an air compressor is specified as 3 m3/min. It means that the compressor is capable of:

Test: Refrigerant Compressors - 1 - Question 10

When a burnt out hermetic compressor is replaced by a new one, it is desirable to include in the system a large drier-cum ·strainer also. This is to be placed in

Test: Refrigerant Compressors - 1 - Question 11

Match List-I (Name of equipment) with List-II (Pressure ratio) and select the correct answer using the code given below the lists:

Test: Refrigerant Compressors - 1 - Question 12

Which one of the following statements is correct?

In reciprocating compressors, one should aim at compressing the air 

Test: Refrigerant Compressors - 1 - Question 13

Roots blower is an example of:

Test: Refrigerant Compressors - 1 - Question 14

Assertion (A): A reciprocating air compressor at sea level would deliver a greater mass of air than a compressor on a mountain.

Reason (R): The compressor ratings are given for “free air”. 

Test: Refrigerant Compressors - 1 - Question 15

Assertion (A): In multi-stage compressors, the polytropic efficiency is always greater than the isentropic efficiency.

Reason(R): Higher the pressure ration, the greater is the polytropic efficiency.

Test: Refrigerant Compressors - 1 - Question 16

During steady flow compression process of a gas with mass flow rate of 2 kg/s. increase in specific enthalpy is 15kJ/kg and decrease in kinetic energy is 2 kJ/kg. The rate of heat rejection to the environment is 3kW. The power needed to drive the compressor is:

Detailed Solution for Test: Refrigerant Compressors - 1 - Question 16

Power needed to drive the compression 

Test: Refrigerant Compressors - 1 - Question 17

When are shock waves formed in air compressors?

Test: Refrigerant Compressors - 1 - Question 18

For a two-stage reciprocating air compressor, the suction pressure is 1.5 bar and the delivery pressure is 54 bar. What is the value of the ideal intercooler pressure? 

Detailed Solution for Test: Refrigerant Compressors - 1 - Question 18

Test: Refrigerant Compressors - 1 - Question 19

What is the preferred intercooler pressure for a two stage air compressor working between the suction pressure ps and the delivery pressure pd?

Test: Refrigerant Compressors - 1 - Question 20

Reciprocating compressors are provided with

Information about Test: Refrigerant Compressors - 1 Page
In this test you can find the Exam questions for Test: Refrigerant Compressors - 1 solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Refrigerant Compressors - 1, EduRev gives you an ample number of Online tests for practice

Top Courses for Mechanical Engineering

Download as PDF

Top Courses for Mechanical Engineering