Chemical Engineering Exam  >  Chemical Engineering Tests  >  Test: Number of Transfer Units - Chemical Engineering MCQ

Test: Number of Transfer Units - Chemical Engineering MCQ


Test Description

10 Questions MCQ Test - Test: Number of Transfer Units

Test: Number of Transfer Units for Chemical Engineering 2024 is part of Chemical Engineering preparation. The Test: Number of Transfer Units questions and answers have been prepared according to the Chemical Engineering exam syllabus.The Test: Number of Transfer Units MCQs are made for Chemical Engineering 2024 Exam. Find important definitions, questions, notes, meanings, examples, exercises, MCQs and online tests for Test: Number of Transfer Units below.
Solutions of Test: Number of Transfer Units questions in English are available as part of our course for Chemical Engineering & Test: Number of Transfer Units solutions in Hindi for Chemical Engineering course. Download more important topics, notes, lectures and mock test series for Chemical Engineering Exam by signing up for free. Attempt Test: Number of Transfer Units | 10 questions in 10 minutes | Mock test for Chemical Engineering preparation | Free important questions MCQ to study for Chemical Engineering Exam | Download free PDF with solutions
Test: Number of Transfer Units - Question 1

Pick the odd one out

Detailed Solution for Test: Number of Transfer Units - Question 1

In surface condenser, the heat transfer occurs between the fluid streams without mixing or physical contact with each other.

Test: Number of Transfer Units - Question 2

The lubricating oil for a large industrial gas turbine engine is cooled in a counter flow, concentric tube heat exchanger. The cooling water flows through the inner tube ( diameter = 25 mm) with inlet temperature 25 degree celsius and mass flow rate 0.2 kg/s. The oil flows through the annulus (diameter = 50 mm) with mass flow rate 0.125 kg/s and its temperature at entry and exit are 90 degree Celsius and 60 degree Celsius. Find outlet temperature of cooling water

Detailed Solution for Test: Number of Transfer Units - Question 2

mc(th1 – th2) = mcc(tc2 – tc1).

1 Crore+ students have signed up on EduRev. Have you? Download the App
Test: Number of Transfer Units - Question 3

A cross flow type air heater has an area of 50 cm2. The overall heat transfer coefficient is 100 W/mK and heat capacity of both hot and cold stream is 1000 W/m K. The value of NTU is

Detailed Solution for Test: Number of Transfer Units - Question 3

Test: Number of Transfer Units - Question 4

In a balanced counter flow heat exchanger with mh c= mcc, the NTU is equal to unity. What is the effectiveness of heat exchanger?

Test: Number of Transfer Units - Question 5

After expansion from a gas turbine, the hot exhaust gases are used to heat the compressed air from a compressor with the help of a cross flow heat exchanger of 0.8 effectiveness. What is the number of transfer units of the heat exchanger?

Detailed Solution for Test: Number of Transfer Units - Question 5

Effectiveness = NTU/NTU – 1 = 0.5.

Test: Number of Transfer Units - Question 6

E – NTU method is particularly useful in thermal design of heat exchangers when

Detailed Solution for Test: Number of Transfer Units - Question 6

It is useful when outlet temperatures of the fluid streams are not known as a priori.

Test: Number of Transfer Units - Question 7

The engine oil at 150 degree Celsius is cooled to 80 degree Celsius in a parallel flow heat exchanger by water entering at 25 degree Celsius and leaving at 60 degree Celsius. Estimate the number of transfer units

Detailed Solution for Test: Number of Transfer Units - Question 7

Effectiveness = 1 – exponential [- NTU (1 – C)]/1 + C.

Test: Number of Transfer Units - Question 8

In a surface condenser, the water flowing through a series of tubes at the rate of 200 kg/hr is heated from 15 degree Celsius to 75 degree Celsius. The steam condenses on the outside surface of tubes at atmospheric pressure and the overall heat transfer coefficient is estimated at 860 k J/m2 hr degree. Find the number of transfer units of the heat exchanger. At the condensing pressure, stream has saturation temperature 0f 100 degree Celsius and the latent heat of vaporization is 2160 k J/kg. Further, the steam is initially just saturated and the condensate leaves the exchanger without sub-cooling i.e. only latent heat of condensing steam is transferred to water. Take specific heat of water as 4 k J/kg K

Detailed Solution for Test: Number of Transfer Units - Question 8

Effectiveness = 1 – exponential [- NTU].

Test: Number of Transfer Units - Question 9

Consider the above problem, find the steam condensation rate

Detailed Solution for Test: Number of Transfer Units - Question 9

mhfg = mc(tc2 – tc1).

Test: Number of Transfer Units - Question 10

NTU is a number of transfer units, dimensionless parameter defined as

Detailed Solution for Test: Number of Transfer Units - Question 10

The number of transfer units is a measure of the size of the heat exchanger, it provides some indication of the size of the heat exchanger.

Information about Test: Number of Transfer Units Page
In this test you can find the Exam questions for Test: Number of Transfer Units solved & explained in the simplest way possible. Besides giving Questions and answers for Test: Number of Transfer Units, EduRev gives you an ample number of Online tests for practice
Download as PDF