Electrical Engineering (EE) Exam  >  Electrical Engineering (EE) Notes  >  Power Systems  >  Power Flow through a Transmission Line

Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE) PDF Download

Introduction

  • So far the transmission line performance equation was presented in the form of voltage and current relationships between sending-and receiving-ends. Since loads are more often expressed in terms of real (watts/kW) and reactive (VARs/kVAR) power, it is convenient to deal with transmission line equations in the form of sending- and receiving-end complex power and voltages. While the problem of Power Flow through a Transmission Line in a general network will be discussed later, the Power Flow through Transmission Line principles involved are illustrated here through a single transmission line (2-node/2-bus system) as shown in Figure.
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Let us take the receiving-end voltage as a reference phasor (VR = |VR| ∠0°) and let the sending-end voltage lead it by an angle δ(VS = |VS| ∠δ). The angle δ is known as the torque angle.
  • The complex power leaving the receiving-end and entering the sending-end of the transmission line can be expressed as (on per phase basis)
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Receiving- and sending-end currents can, however, be expressed in terms of receiving- and sending-end voltages as
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Let A, B, D, the transmission line constants, be written as
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Therefore, we can write
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Substituting for IR in Eq. (5.54) we get
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Similarly,
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • In the above equations SR and SS are per phase complex voltamperes, while Vand VS are expressed in per phase volts. If VR and VS are expressed in kV line, then the three-phase receiving-end complex power is given by
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • This indeed is the same as Eq. (5.58). The same result holds for SS. Thus we see that Eqs. (5.58) and (5.59) give the three-phase MVA if VS and VR are expressed in kV line.
  • If Eq. (5.58) is expressed in real and imaginary parts, we can write the real and reactive powers at the receiving-end as
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Similarly, the real and reactive powers at sending-end are
  • It is easy to see from Eq. (5.61) that the received power PR will be maximum at
    δ = β
  • such that
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • The corresponding QR (at max PR) is
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Thus the load must draw this much leading MVAR in order to receive the maximum real power.
  • Consider now the special case of a short line with a series impedance Z. Now
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Substituting these in Eqs. (5.61) to (5.64), we get the simplified results for the short line as
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • for the receiving-end and for the sending-end
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • The above short line equation will also apply for a long line when the line is replaced by its equivalent- π (or nominal- π) and the shunt admittances are lumped with the receiving-end load and sending-end generation.
  • From Eq.(5.66), the maximum receiving-end power is received, when δ = θ
    so that
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
    Now cos θ = R/|Z|,
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Normally the resistance of a transmission line is small compared to its reactance (since it is necessary to maintain a high efficiency of transmission), so that θ = tan-1 X/R ≈ 90; where Z = R + jX. The receiving-end Eqs. (5.66) and (5.67) can then be approximated as
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Equation (5.72) can be further simplified by assuming cos δ ≈ 1, since δ is normally small. Thus
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
  • Let |VS| – |VR| = |ΔV|, the magnitude of voltage drop across the transmission line.
    Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)

Several important conclusions that easily follow from Eqs. (5.71) to (5.74) are enumerated below:

  • For R ≈ 0 (which is a valid approximation for a transmission line) the real power transferred to the receiving-end is proportional to sin δ ( ≈ δ for small values of δ ), while the reactive power is proportional to the magnitude of the voltage drop across the line.
  • The real power received is maximum for δ = 90° and has a value |Vs||VR|/X. Of course, δ is restricted to values well below 90° from considerations of stability.
  • Maximum real power transferred for. a given line (fixed X) can be increased by raising its voltage level. It is from this consideration that voltage levels are being progressively pushed up to transmit larger chunks of Power Flow through Transmission Line over longer distances warranted by large size generating stations. For very long lines voltage level cannot be raised beyond the limits placed by present-day high voltage technology. To increase power transmitted in such cases, the only choice is to reduce the line reactance. This is accomplished by adding series capacitors in the line. Series capacitors would of course increase the severity of line over voltages under switching conditions.
  • As said in 1 above, the VARs (lagging reactive power) delivered by a line is proportional to the line voltage drop and is independent of δ. Therefore, in a transmission system if the VARs demand of the load is large, the voltage profile at that point tends to sag rather sharply. To maintain a desired voltage profile, the VARs demand of the load must be met locally by employing positive VAR generators (condensers).

A somewhat more accurate yet approximate result expressing line voltage drop in terms of active and reactive Power Flow through Transmission Line can be written, i.e.

Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)
This result reduces to that of Eq. (5.74) if R = 0.

The document Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE) is a part of the Electrical Engineering (EE) Course Power Systems.
All you need of Electrical Engineering (EE) at this link: Electrical Engineering (EE)
21 videos|67 docs|45 tests

Top Courses for Electrical Engineering (EE)

21 videos|67 docs|45 tests
Download as PDF
Explore Courses for Electrical Engineering (EE) exam

Top Courses for Electrical Engineering (EE)

Signup for Free!
Signup to see your scores go up within 7 days! Learn & Practice with 1000+ FREE Notes, Videos & Tests.
10M+ students study on EduRev
Related Searches

past year papers

,

Previous Year Questions with Solutions

,

mock tests for examination

,

Extra Questions

,

shortcuts and tricks

,

Sample Paper

,

Exam

,

study material

,

pdf

,

practice quizzes

,

Summary

,

video lectures

,

Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)

,

Free

,

MCQs

,

Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)

,

Important questions

,

Viva Questions

,

Semester Notes

,

ppt

,

Objective type Questions

,

Power Flow through a Transmission Line | Power Systems - Electrical Engineering (EE)

;