NEET Exam  >  NEET Notes  >  Physics Class 12  >  Theory & Procedure, Conversion of Galvanometer to Ammeter

Theory & Procedure, Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET PDF Download

Our Objective:

To convert the given galvanometer (of known resistance and figure of merit) into an ammeter of desired range and to verify the same.

The Theory:

What is a Galvanometer?

A galvanometer is a device used to detect feeble electric currents in a circuit.  It has a coil pivoted (or suspended) between concave pole faces of a strong laminated horse shoe magnet.  When an electric current passes through the coil, it deflects.   The deflection is proportional to the current passed. The galvanometer coil has a moderate resistance (about 100 ohms) and the galvanometer itself has a small current carrying capacity (1 mA).

What is an Ammeter?

An ammeter is a device used for measuring large electric currents in circuits.  For this purpose, it is put in series with the circuit in which the current is to be measured.

How to convert a Galvanometer into an Ammeter?

A galvanometer can detect only small currents.  Thus, to measure large currents it is converted into an ammeter.  It can be converted into an ammeter by connecting a low resistance called shunt resistance in parallel to the galvanometer.

Let G be the resistance of the galvanometer and Ig be the current for full scale deflection in the galvanometer, the value of the shunt resistance required to convert the galvanometer into an ammeter of 0 to I ampere is,

S = I g × G I − I g

Ig is calculated using the equation, Ig = nk, where n is the number of divisions on the galvanometer and k is the figure of merit of galvanometer.

What is figure of merit of a galvanometer?

The figure of merit of a galvanometer is defined as the current required in producing a unit deflection in the scale of the galvanometer.  It is represented by the symbol k and is given by the equation,

Theory & Procedure, Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET

Where E is the e.m.f. of the cell and θ is the deflection produced with resistance R.

Let ‘l’ be the length of the resistance wire required for a resistance of S ohm,

Theory & Procedure, Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET

where, r is the radius of the wire and ρ is the resistivity of the material of the wire.

Learning Outcomes:

The student learns the following concepts:

  • Galvanometer
  • Ammeter
  • Figure of merit
  • Shunt resistance
  • How a galvanometer can be converted into an ammeter.

Materials required:

  • Galvanometer
  • Cell
  • Rheostat
  • Ammeter of desired range
  • Resistance wire
  • Key
  • Screw gauge

Real Lab Procedure:

  • The shunt resistance required to convert the galvanometer into ammeter of range I is calculated using the formula,

Theory & Procedure, Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET    

G- the resistance of the galvanometer.
I- the range of desired ammeter
Ig = nk, the current required for full scale deflection in the galvanometer,
where, n- total number of divisions in the galvanometer
k- the figure of merit of the galvanometer.
Then, the length of the wire required for shunt can be calculated using the formula,
 Theory & Procedure, Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET
Where, ρ- the resistivity of material of the wire
r- the radius of the wire, which can be measured using a screw gauge.

  • Cut the resistance wire at a length of (l+2) cm.
  • Make two marks near the ends of the wire so that the distance between the marks is exactly l cm.
  • The wire is now connected to the terminals of the galvanometer so that the marks are just outside the terminals of the galvanometer.
  • The galvanometer with the shunt connected across its terminals is the converted ammeter of the desired range.
  • Connections are made as shown in the circuit diagram.

Theory & Procedure, Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET

  • The galvanometer with shunt resistance is connected in series to a battery through an ammeter, key and rheostat.
  • Insert the key.
  • Adjust the rheostat and set the current reading I of the given ammeter at a particular value.
  • The reading of the galvanometer Ig’ is noted. Now, the current through the converted ammeter is calculated using the relation,
    Theory & Procedure, Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET            
  • The error of the converted ammeter is calculated as I – I’.

Repeat the experiment by changing the rheostat resistance.

  • A graph can be drawn with (I – I’) along Y-axis and I’ along X-axis. This is called the correction graph.
  • Thus, the converted ammeter is verified with an ammeter of the same range and a correction graph is obtained.

Simulator procedure (as performed through the Online Labs):

  • Select the ammeter range (I) from the drop down list.
  • Select the galvanometer resistance (G) from the drop down list.
  • Select the galvanometer range (n-total number of divisions on the galvanometer) from the drop down list.
  • The cell voltage is fixed as 2V.
  • Select the material of the wire from the drop down list.
  • The radius of platinum wire is fixed as 0.1 mm and others is 0.2 mm.
  • Enter the calculated value of shunt resistance (S), rounded for two digits, in the text box.
  • Click on the ‘Submit’ button to verify your value.
  • If the value is correct, enter the length (l) of the wire required for shunt, rounded for two digits, in the text box.
  • Click on the ‘Submit’ button to verify your value.
  • If the value is correct, click on the ‘Proceed’ button to go to the experiment.
  • To see the circuit diagram, click on the 'Show/hide circuit diagram' check box seen inside the simulator window.
  • Connections can be made as seen in the circuit diagram by clicking and dragging the mouse from one connecting terminal to the other connecting terminal of the devices to be connected.
  • To insert the key, click on the ‘Insert key’ button.
  • You can change the rheostat resistance using the slider.
  • You can notice the corresponding ammeter and voltmeter readings.
  • To redo the experiment, click on the ‘Reset’ button.

Observations:

Resistance of the galvanometer, G = ............ohms
Figure of merit of the galvanometer, k = ............... amp./div.
Number of divisions in the galvanometer scale, n = ................
Current for full scale deflection, Ig = nk =............amp.

Desired range of the converted ammeter (I) ---------mA

Shunt resistance,

Theory & Procedure, Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET

The document Theory & Procedure, Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET is a part of the NEET Course Physics Class 12.
All you need of NEET at this link: NEET
105 videos|425 docs|114 tests

Top Courses for NEET

FAQs on Theory & Procedure, Conversion of Galvanometer to Ammeter - Physics Class 12 - NEET

1. What is the theory behind converting a galvanometer to an ammeter?
Ans. The theory behind converting a galvanometer to an ammeter involves connecting a shunt resistor in parallel with the galvanometer. The shunt resistor allows a known fraction of the current to bypass the galvanometer, enabling the measurement of larger currents.
2. What is the procedure for converting a galvanometer to an ammeter?
Ans. The procedure for converting a galvanometer to an ammeter involves selecting an appropriate shunt resistor with a known resistance value. The shunt resistor is then connected in parallel to the terminals of the galvanometer. The ammeter is calibrated by adjusting the shunt resistor's value until the desired current range is achieved.
3. How does the conversion of a galvanometer to an ammeter affect the galvanometer's sensitivity?
Ans. The conversion of a galvanometer to an ammeter reduces the galvanometer's sensitivity. This is due to the addition of the shunt resistor, which diverts a portion of the current away from the galvanometer. The galvanometer's sensitivity is inversely proportional to the shunt resistance value.
4. Can any galvanometer be converted into an ammeter?
Ans. Not all galvanometers can be converted into ammeters. The suitability of a galvanometer for conversion depends on its internal resistance and current range. Galvanometers with low internal resistance and a current range compatible with the desired ammeter range are generally suitable for conversion.
5. What are the advantages of converting a galvanometer to an ammeter?
Ans. Converting a galvanometer to an ammeter offers several advantages. It allows the measurement of larger currents by diverting a known fraction of the current away from the galvanometer. It also extends the range of the galvanometer, making it more versatile for various current measurements. Additionally, it is a cost-effective solution compared to purchasing a dedicated ammeter.
105 videos|425 docs|114 tests
Download as PDF
Explore Courses for NEET exam

Top Courses for NEET

Signup for Free!
Signup to see your scores go up within 7 days! Learn & Practice with 1000+ FREE Notes, Videos & Tests.
10M+ students study on EduRev
Related Searches

study material

,

ppt

,

MCQs

,

practice quizzes

,

Exam

,

video lectures

,

Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET

,

Free

,

pdf

,

mock tests for examination

,

Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET

,

Viva Questions

,

Conversion of Galvanometer to Ammeter | Physics Class 12 - NEET

,

shortcuts and tricks

,

Extra Questions

,

Important questions

,

Semester Notes

,

Previous Year Questions with Solutions

,

Sample Paper

,

Summary

,

Theory & Procedure

,

Theory & Procedure

,

past year papers

,

Objective type Questions

,

Theory & Procedure

;